نتایج جستجو برای: photon attenuation

تعداد نتایج: 118713  

2013
Peng He Biao Wei Peng Feng Mianyi Chen Deling Mi

Spectral/multienergy CT employing the state-of-the-art energy-discriminative photon-counting detector can identify absorption features in the multiple ranges of photon energies and has the potential to distinguish different materials based on K-edge characteristics. K-edge characteristics involve the sudden attenuation increase in the attenuation profile of a relatively high atomic number mater...

2005
Axel Martinez-Möller Nassir Navab Markus Schwaiger Stephan G. Nekolla

The purpose of this work is to understand, quantify and minimize the impact of the emission-transmission misalignment which has been reported as a source of artefacts in cardiac PET/CT. A new and fully automatic correction algorithm is proposed to realign the μ-map contour of the left ventricle to the measured PET. PET/CT NH3 rest/stress scans were acquired for 16 patients in order to evaluate ...

1999
Volker Dicken V Dicken

In single photon emission computed tomography (SPECT) one is interested in reconstructing the activity distribution f of some radiopharmaceutical. The data gathered suffer from attenuation due to the tissue density μ. Each imaged slice incorporates noisy sample values of the nonlinear attenuated Radon transform A(f,μ)(ω, s) = ∫ ∞ −∞ f (sω⊥ + tω) exp (

Journal: :Physical review letters 2014
H Gorniaczyk C Tresp J Schmidt H Fedder S Hofferberth

We report on the realization of an all-optical transistor by mapping gate and source photons into strongly interacting Rydberg excitations with different principal quantum numbers in an ultracold atomic ensemble. We obtain a record switch contrast of 40% for a coherent gate input with mean photon number one and demonstrate attenuation of source transmission by over ten photons with a single gat...

2012
Kazuhiro Koshino Kazuhito Fukushima Masaji Fukumoto Kazunari Sasaki Tetsuaki Moriguchi Yuki Hori Tsutomu Zeniya Yoshihiro Nishimura Keisuke Kiso Hidehiro Iida

BACKGROUND Attenuation correction of a single photon emission computed tomography (SPECT) image is possible using computed tomography (CT)-based attenuation maps with hybrid SPECT/CT. CT attenuation maps acquired during breath holding can be misaligned with SPECT, generating artifacts in the reconstructed images. The purpose of this study was to investigate the effects of respiratory phase duri...

A. Vyas P. Kumar R. Ravanfar Haghighi S. Chatterjee,

Introduction: The photoelectric attenuation coefficient of substances is known to depend upon the energy E of the photon and the effective atomic number of substances (Zeff) as (Zeffx/Ey).  No definitive values about these indices x, y are given in the literature. The index x is said to lie between, 3.0 and 4.0, while for ‘y’ different values have been assigned, between 3.0 and 4.0. Method...

Journal: :Physics in medicine and biology 1999
J H Hubbell

The probability of a photon (x-ray, gamma-ray, bremsstrahlung, etc) of a given energy E undergoing absorption or scattering when traversing a layer of material Z can be expressed quantitatively in terms of a linear attenuation coefficient mu (cm(-1)). Since mu is dependent on the material's density, rho (g cm(-3)), which can be variable, the quantity usually tabulated is the mass attenuation co...

2017
F. Seif M.J. Tahmasebi-Birgani M.R. Bayatiani

BACKGROUND In this study, a method for linear attenuation coefficient calculation was introduced. METHODS Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. RESULTS The val...

2015
Sachiko Yamada Takashi Ueguchi Eku Shimosegawa Koichi Fujino Takeshi Shimazu Kenya Murase Jun Hatazawa

Objective: Computed tomography (CT)-based attenuation correction (CTAC) offers the clear benefit of reliable reconstruction of single-photon emission computed tomography (SPECT) images through its ability to achieve object-specific attenuation maps, but artifacts from dense materials often deteriorate CTAC performance. Therefore, we investigate the feasibility of CTAC in the presence of dense m...

Journal: :iranian journal of nuclear medicine 2013
mohsen hajizadeh saffar shabnam oloomi peter knoll hadi taleshi

introduction: scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. accurate estimation of scatter in projection data of spect is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. methods: the objective of this paper is to develop and validate a scatter correction technique ...

نمودار تعداد نتایج جستجو در هر سال