نتایج جستجو برای: np control chart

تعداد نتایج: 1388409  

Journal: :Int. J. Computer Integrated Manufacturing 2011
F. Zandi Seyed Taghi Akhavan Niaki M. A. Nayeri M. Fathi

Despite the fact that control charts are able to trigger a signal when a process has changed, it does not indicate when the process change has begun. The time difference between the changing point and a signal of a control chart could cause confusions on the sources of the problems. Knowing the exact time of a process change would help to reduce the time for identification of the special cause....

The CCC-r chart is developed based on cumulative count of a conforming (CCC) control chart that considers the cumulative number of items inspected until observing r nonconforming ones. Typically, the samples obtained from the process are analyzed through 100% inspection to exploit the CCC-r chart. However, considering the inspection cost and time would limit its implementation. In this paper, w...

Journal: :journal of periodontology and implant dentistry 0
reza amid maryam torshabi kasra tabari mahdi kadkhodazadeh sarah eslami mitra ghazizadeh ahsaie

background and aims. the aim of this study was to compare the biocompatibility of calcium-enriched mixture ce-ment (cem), composite resin and nano-particled mineral trioxide aggregate (np-mta) using human gingival fibroblasts. materials and methods. a comparative in vitro cell culture study was carried out using 60 single-rooted teeth which were assigned to the following four groups: 1) untreat...

Journal: :iranian journal of science and technology (sciences) 2014
m. riaz

in statistical quality control a very widely used measure is average run length (arl) which may be worked out by different methods like integral equation, approximations, and monte carlo simulations. the arl measure and the other related measures are of major significance in every type of production process. an omission in its computation (and hence its related measures such as extra quadratic ...

In many processes in real practice at the start-up stages the process parameters are not known a priori and there are no initial samples or data for executing Phase I monitoring and estimating the process parameters. In addition, the practitioners are interested in using one control chart instead of two or more for monitoring location and variability of processes. In this paper, we consider a s...

Statistical process control methods for monitoring processes with univariate ormultivariate measurements are used widely when the quality variables fit to known probabilitydistributions. Some processes, however, are better characterized by a profile or a function of qualityvariables. For each profile, it is assumed that a collection of data on the response variable along withthe values of the c...

2016
Mercedes Pineda Eugen Mengel Helena Jahnová Bénédicte Héron Jackie Imrie Charles M. Lourenço Vanessa van der Linden Parvaneh Karimzadeh Vassili Valayannopoulos Pavel Jesina Juan V. Torres Stefan A. Kolb

BACKGROUND Niemann-Pick disease Type C (NP-C) is difficult to diagnose due to heterogeneous and nonspecific clinical presentation. The NP-C Suspicion Index (SI) was developed to identify patients with a high likelihood of NP-C; however, it was less reliable in patients aged <4 years. METHODS An early-onset NP-C SI was constructed following retrospective chart review of symptom presentation in...

Saghaei, A., Shokrizadeh, R., Yaquninejad , Y.,

When the objective is quick detection both small and large shifts in the process mean with normal distribution, the generalized likelihood ratio (GLR) control charts have better performance as compared to other control charts. Only the fixed parameters are used in Reynolds and Lou’s presented charts. According to the studies, using variable parameters, detect process shifts faster than fixed pa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید