نتایج جستجو برای: nano cantilever
تعداد نتایج: 55461 فیلتر نتایج به سال:
This paper reports quantitative topographical measurements using a heated atomic force microscope (AFM) cantilever probe. The study compares opographies measured by the cantilever thermal signal to topographies measured by the laser-deflection signal of an AFM system. The experiment sed 20 and 100 nm tall Si gratings as topographical test samples. The cantilever heater temperature ranged from 1...
This paper presents a tactile transducer device that is optimized from biomechanical data and has a compact, yet modular design. The tactile transducer comprises a 6 × 10 piezo bimorph actuator array with a spatial resolution of 1.8 × 1.2 millimeters and a wide temporal bandwidth. The actuator mounting method was improved from a conventional cantilever method to a dual-pinned method, giving the...
در این رساله، طراحی، اجراء و مدلسازی فرآیند nano-edm مورد بررسی و تحقیق قرار گرفت. به منظور تولید نانو- ابزار مناسب برای فرآیند nano-edm یک دستگاه اتوماتیک طراحی و ساخته شد که با استفاده از آن، تاثیر متغیرهای فرآیند ساخت بر خصوصیات نانو- ابزار مورد تحقیق قرار گرفت. با شناسایی سطوح بهینه متغیرهای فرآیند ساخت به روش تاگوچی، نانو- ابزارهایی با شعاع نوک حدود 10 نانومتر و ضریب جانبی (نسبت طول به شعا...
This paper focuses on the development of a complete model of an atomic force microscope (AFM) micro-cantilever beam, based on considering the effects of four major factors in modeling the cantilever. They are: rotary inertia and shear deformation of the beam and mass and rotary inertia of the tip. A method based on distributed-parameter modeling approach is proposed to solve the governing equat...
This study selected forty-two implants with full arch implantsupported fixed prostheses (with and without a cantilever) with at least five years' loading. Radiographic measurements were performed using Digimizer software (MedCalc Software, Belgium). Bone loss was measured on the distal side of the implant, from the surface of the platform to the edge of the bone crest, and the extent of the can...
one of the bio-sensing mechanisms is mechanical. rather than measuring shift in resonance frequency, we adopt to measure the change in spring constant due to adsorption, as one of the fundamental sensing mechanism. this study explains determination of spring constant of a surface functionalized micro machined micro cantilever, which resonates in a trapezoidal cavity-on silicon wafer, with the ...
The presence of van der Waals (vdW) force can lead to mechanical instability in freestanding nano-scale actuators. Most of the previous researches in this area have exclusively focused on modeling the instability in actuators with one actuating components. While, less attention has been paid to actuators consist of two actuating components. Herein, the effect of the vdW force on the instability...
The quantitative measurement of viscoelasticity nano-scale entities is an important goal nanotechnology research and there considerable progress with advent dynamic atomic force microscopy. hydrodynamics cantilever, the sensor in AFM measurements, plays a pivotal role estimates viscoelasticity. point-mass (PM) model, wherein cantilever approximated as mass-less spring widely used analysis its v...
We present a novel ultrasensitive magnetometry technique using a micromachined magnetic cantilever that is brought in resonance. The induced magnetic moment generates a torque on the cantilever, thereby effectively stiffening the cantilever spring constant and changing its resonance frequency. Experiments are in good correspondence with the presented analytical model for this frequency shift, p...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید