Background: This study investigated the γ-rays shielding properties of some building materials in Sudan has been investigated. Materials and Methods: Photons attenuation coefficients and half value layer (HVL) were experimented using Cs-137 and Co-60 sources. The measurements were performed to gauge the intensity of radiation when performed unshielded, the specific thickness of selected sample...
BACKGROUND Radiation-therapy is a complex process with multiple steps, each of which has an impact on the quality of treatment. Accurate dosimetry is a critical step during the radiotherapy of cancer patients.The aim of the present study was to measure and evaluate the doses of two cobalt- 60 (60Co) teletherapy units GWXJ80 of NPIC China and Theratron 780 of AECL Canada at various points within...
PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...
Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...
Satisfactory discrimination between the neutron and gamma components in a mixed neutron-gamma field is one of most important objectives dosimetry. One common techniques for estimating dose fields two peak method. This method has been applied using dosimeters such as LiF:Mg,Ti, but present work, 6LiF:Mg,Cu,P dosimeter used, whose thermoluminescence sensitivity much higher than LiF:Mg,Ti dosimete...
An a-Si Active Matrix Flat Panel Imager (AMFPI) prototype developed in-house has been modified to function as an in-phantom dosimetry system providing high resolution two-dimensional (2-D) data. This Active Matrix Flat Panel Dosimeter (AMFPD) system can be used as a replacement device for standard in-phantom dosimeters, such as scanning ion chambers in water, or film in solid water. The initial...
Cobalt nanoparticles were synthesized using the gamma radiolytic technique, and particle size was found to be reduced from 12±1 7±1 nm by increasing dose 10 60 kGy. The UV-visible absorption spectra measured exhibited a steady maxima at 517 in UV region, which blue-shifted toward lower wavelength with decrease size. By taking conduction electrons of an isolated that are not entirely free but in...
PURPOSE To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. METHODS The standard method (AAPM's TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 c...
Histamine H2 receptor antagonist are used in the clinical treatment of peptic ulcer. In vitro metaphase analysis and micronucleus assay were used to test the effect of Famotidine & Ranitidine on 60 Cobalt gamma-ray induced clastogenic effects. Heparinised whole blood was obtained from 6 healthy volunteers and was gamma irradiated with 3Gy. Lymphocyte cultures were initiated and aqueous solution...