نتایج جستجو برای: inlet air cooling systems
تعداد نتایج: 1417419 فیلتر نتایج به سال:
The main objective of this investigation was to design and investigate a radiant panel cooling system on small scale building type (office) under the central Sudan climatic conditions so as to explore the benefits of radiant cooling systems over conventional air conditioning systems (Variable air volume systems). Transient heat conduction of building (finite difference method) was used to evalu...
A good cooling inside a battery pack is important to avoid safety issues and avoid the development of too large internal temperature gradients. The temperature distributions inside two packs (in-line and staggered) made of large cylindrical lithium iron phosphate cells (of 18 Ah nominal capacity) are analysed in this paper during a 90 A constant discharge current. The analysis of the battery pa...
In this paper, a data-based mechanistic modelling approach was developed to real time monitoring and online adaptive control of three-dimensional temperature distribution in both an individual biological product and in a given movement. Boxes of potatoes were used as biological material. During the experiments, step inputs on an air inlet temperature were applied while airspace and potatoes tem...
I:U+ Abstract Length-sorted lumber is surfaced on one side t() 1.75-inch thickness, mechanically stacked 5 feet wide and 10 feet high on 1-1/4-inch-thick sticks, and continuously transported through a zone-controlled tunnel kiln at 8 ft./hr. t() yield 500,000 tbm of lumber dried t() 9 percent average MC per 168hour week. In the tunnel, the lumber is dried for 8 (possibly 10) hours at 270°F, con...
The energy performance of radiant slab cooling relative to conventional air systems to be clarified for climates from cold and dry to very hot and humid. EnergyPlus simulations were used to compare the energy performance of 1) radiant slab cooling combined with a dedicated outdoor air system and 2) a variable air volume system. Simulation results show that the radiant slab system provided 10% t...
Free cooling techniques can be used to substantially reduce energy costs. During cold weather, the outside ambient temperature can help in saving energy in refrigeration systems. The low temperature of the cooling ambient air supply enables free cooling technique to store fresh fruits and vegetables. This energy-efficiency measure can save enough compressor electric power to pay for modulating ...
Background and aimsThe catalytic ozonation is an efficient process for the degradation of volatile organic compounds from contaminated air stream. This study was aimed at investigating the efficacy of catalytic ozonation process in removal of xylene from the polluted air stream andthe influence of retention time (gas flow rate), inlet ozone dose and relative humidity on this performanceMethodst...
Performance of a gas turbine is mainly depends on the inlet air temperature. The power output of a gas turbine depends on the mass flow rate of air. Now days the atmosphere temperature is hot, so the air is less density, the mass flow rate will reduce and automatically the power output will reduce. A reduce of 1°C temperature of inlet air increases the power output by approximately 0.7MW. To re...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید