نتایج جستجو برای: inhomogeneity correction
تعداد نتایج: 170481 فیلتر نتایج به سال:
A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...
For patients treated with lung stereotactic body radiation therapy (SBRT) using dynamic conformal arcs, the influence of inhomogeneity correction (IC) on normal tissue and tumor dosimetry was studied. For the same numbers of monitor units, the planning target volume equivalent uniform doses calculated without path-length IC were lower than those calculated with IC (mean difference 18%, range 1-...
A number of treatment-planning systems still use conventional correction methods for body inhomogeneities. Most of these methods (power law method, tissue-air ratio (TAR), etc.) consider only on-axis points, rectangular fields, and inhomogeneous slabs covering the whole irradiating field. A new method is proposed that overcomes the above limitations. The new method uses the principle of the Cla...
In echo-planar imaging (EPI), such as commonly used for functional MRI (fMRI) and diffusion-tensor imaging (DTI), compressed distortion is a more difficult challenge than local stretching as spatial information can be lost in strongly compressed areas. In addition, the effects are more severe at ultra-high field (UHF) such as 7T due to increased field inhomogeneity. To resolve this problem, two...
CONCLUSIONS A field-corrected imaging approach to sparsely-sampled fMRI data has been presented. The method exploits the specific low-rank structure of fMRI data via group sparsity and incorporates field inhomogeneity into iterative image reconstruction. Experimental results demonstrate the ability of the method in obtaining higher-resolution functional images and activation maps with artifact ...
The single breath method underestimates total lung capacity by comparison with the multiple breath method (TLCmb) because of inhomogeneity of ventilation distribution. This study proposes a simple correction for the single breath TLC (TLCsb), using inert gas phase III slope to account for the effects of uneven ventilation distribution. A model of a non-uniform lung ventilation was designed, com...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید