نتایج جستجو برای: inflow control device icd

تعداد نتایج: 1924623  

Hedayati, Mohammadtaghi, Jalalian, Rozita, Saravi, Mehrdad,

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

2017
Yusuke Kondo Marehiko Ueda Joachim Winter Miyo Nakano Masahiro Nakano Masayuki Ishimura Kazuo Miyazawa Kaoru Tateno Yoshio Kobayashi

The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful in...

Journal: :Chest 2001
M H Gollob J J Seger

Clinical trials have established the superiority of the implantable cardioverter-defibrillator (ICD) over antiarrhythmic drug therapy in survivors of sudden cardiac death and in high-risk patients with coronary artery disease. The ICD has evolved to overcome the limitation of earlier devices that required thoracotomy for implantation and were fraught with inappropriate shock delivery. Current I...

2016
Jeremy W. Docekal Mark C. Haigney Joseph C. Lee Matthew Needleman

Introduction Inappropriate shocks from implantable cardioverterdefibrillator (ICD) devices are a well-described clinical problem that contributes to patient morbidity and mortality. There are a number of causes for inappropriate ICD discharge, and T-wave oversensing (TWOS) is one such example. Improvements in ICD sensing algorithms have reduced the incidence of inappropriate therapies but have ...

2015
Omid Kiamanesh Deirdre O’Neill Soori Sivakumaran Shane Kimber

Introduction The implantable cardioverter-defibrillator (ICD) has reduced mortality in survivors of sudden cardiac arrest and patients at high risk of sudden cardiac death. This benefit comes at the cost of device-related complications, including those related to transvenous leads. The subcutaneous ICD (S-ICD) is an alternative to the conventional transvenous ICD (TV-ICD) system and has no tran...

Journal: :International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases 2015
Hea Won Ann Jin Young Ahn Yong Duk Jeon In Young Jung Su Jin Jeong Boyoung Joung MoonHyoung Lee Nam Su Ku Sang Hoon Han June Myung Kim Jun Yong Choi

OBJECTIVES The use of cardiac implantable electronic device (CIED; pacemakers, implantable cardioverter-defibrillators [ICD], cardiac re-synchronized therapy [CRT]) implantation, one essential treatment for cardiac arrhythmias, is increasing. Infectious complications related to implants are the main reason for device removal and patient morbidity. We sought to identify the incidence of infectio...

Journal: :Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2013
Jordana Kron William Sauer Joseph Schuller Frank Bogun Thomas Crawford Sinan Sarsam Lynda Rosenfeld Teferi Y Mitiku Joshua M Cooper Davendra Mehta Arnold J Greenspon Matthew Ortman David B Delurgio Ravinder Valadri Calambur Narasimhan Nalla Swapna Jagmeet P Singh Stephan Danik Steven M Markowitz Adrian K Almquist Andrew D Krahn Luke G Wolfe Shawn Feinstein Kenneth A Ellenbogen

AIMS Implantable cardiac defibrillator (ICD) implantation is a class IIA recommendation for patients with cardiac sarcoidosis (CS). However, little is known about the efficacy and safety of ICDs in this population. The goal of this multicentre retrospective data review was to evaluate the efficacy and safety of ICDs in patients with CS. METHODS AND RESULTS Electrophysiologists at academic med...

Journal: :Circulation. Cardiovascular quality and outcomes 2017
Yvonne May Fen Chia Tiew-Hwa Katherine Teng Eugene S J Tan Wan Ting Tay A Mark Richards Calvin Woon Loong Chin Wataru Shimizu Sang Weon Park Chung-Lieh Hung Lieng H Ling Tachapong Ngarmukos Razali Omar Bambang B Siswanto Calambur Narasimhan Eugene B Reyes Cheuk-Man Yu Inder Anand Michael R MacDonald Jonathan Yap Shu Zhang Eric A Finkelstein Carolyn S P Lam

BACKGROUND Implantable cardioverter defibrillators (ICDs) are lifesaving devices for patients with heart failure (HF) and reduced ejection fraction. However, utilization and determinants of ICD insertion in Asia are poorly defined. We determined the utilization, associations of ICD uptake, patient-perceived barriers to device therapy and, impact of ICDs on mortality in Asian patients with HF. ...

2005
Jeremy N. Ruskin

The automatic implantable cardioverter-defibrillator (ICD) is highly effective in reducing sudden death rates in patients with life-threatening ventricular tachyarrhythmias. However, the magnitude of the ability of the ICD to improve overall survival is less certain. Data supporting the contention that the ICD prolongs survival are reviewed. It is evident that the mortality benefit consequent t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید