نتایج جستجو برای: hip prostheses
تعداد نتایج: 72221 فیلتر نتایج به سال:
Nickel concentrations were analyzed by electrothermal atomic absorption spectrophotometry in serum and whole blood specimens from patients 9 to 15 years after unilateral (N = 11) or bilateral (N = 2) hip arthroplasty. The hip prostheses were of the "Charnley" or "TR-28" (metal-to-plastic) types, fabricated of stainless-steel (14 to 16 percent Ni) with polyethylene acetabular cups. In 12 of the ...
The objective was to evaluate the presence and distribution of the lubricating and anti-adhesion glycoprotein lubricin and cells containing the contractile isoform smooth muscle α-actin (SMA) in pseudomembranes around loose hip prostheses. Periprosthetic tissue was obtained at revision arthroplasty of eight aseptic, loose hip implants, and for comparison three loose knee prostheses. Immunohisto...
BACKGROUND Short-stem (SS) prostheses require less resection of the femoral neck, produce a more physiological load pattern in the proximal femur, reduce stress shielding, and aid bone conservation and are, therefore, beneficial for young patients. Conventional cementless implants in total hip arthroplasty (THA) have shown excellent clinical results; however, it is unclear whether SS prostheses...
PURPOSE To develop methods for qualitative and quantitative evaluation of MRI artifacts near metallic prostheses, and to compare the efficiency of different artifact suppression techniques with different types of hip prostheses. METHODS Three hip prostheses of cobalt-chromium, stainless steel, and titanium were embedded in agarose gel together with a rectilinear grid. Coronal MR images of the...
Using the Trent regional arthroplasty register, we analysed the survival at ten years of 1198 consecutive Charnley total hip replacements carried out across a single health region of the United Kingdom in 1990. At ten years, information regarding outcome was available for 1001 hips (83.6%). The crude revision rate was 6.2% (62 of 1001) and the cumulative survival rate with revision of the compo...
The tribological performance of artificial hip joints is a critical issue for their success, because adverse tissue reaction to wear debris causes loosening and failure. Many studies on wear and lubrication of hip prostheses have been published in the last 10 years, mostly on experimental tests. Theoretical/ numerical models have been proposed for investigating geometrical and material paramete...
The benefits of converting an ankylosed or arthrodesed hip to total hip arthroplasty have been reported in the literature as have the technical difficulties associated with this procedure. This review, however, outlines the experience of a single surgeon (WJMB) at a single institution using uncemented prostheses. Between November 1991 and June 1996, 5 arthrodesed hips underwent uncemented total...
Modern unipolar hip hemiarthroplasty, commonly used for displaced femoral neck fracture, is now modular, with both a variable length cobalt-chromium adapter-sleeve and large femoral head. Patients with these modular components may develop symptomatic trunnion corrosion, with elevated serum metal levels. We report the case of an 82-year-old woman, 5.5 years after a modular unipolar hip hemiarthr...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید