نتایج جستجو برای: harmonic load modelling

تعداد نتایج: 353246  

2014
M. Pattnaik

This paper reports the performance of a speed sensorless stand-alone Variable Speed Constant Frequency (VSCF) Doubly Fed Induction Generator (DFIG) capable of supplying all types of loads. The proposed method maintains the Total Harmonic Distortion (THD) of the machine current and the load voltage within acceptable limits. In contrast to previously proposed methods, in this paper, the stator si...

2015
Jongmin Sung Suman Nag Kim I Mortensen Christian L Vestergaard Shirley Sutton Kathleen Ruppel Henrik Flyvbjerg James A Spudich

Molecular motors are responsible for numerous cellular processes from cargo transport to heart contraction. Their interactions with other cellular components are often transient and exhibit kinetics that depend on load. Here, we measure such interactions using 'harmonic force spectroscopy'. In this method, harmonic oscillation of the sample stage of a laser trap immediately, automatically and r...

Journal: :Journal of applied biomechanics 2015
Jianhua Wu Toyin Ajisafe Matthew Beerse

This study used both time and frequency domain analyses to investigate walking patterns with ankle load in children and adults. Twenty-two children aged 7-10 years and 20 young adults participated in this study. Three levels of ankle load were manipulated: no load, low load (2% of body mass on each side), and high load (4% of body mass on each side). An instrumented treadmill was used to regist...

2005
R. Follmann

In this paper we demonstrate the influence of models non-linearities to harmonic balance simulation software, such as Agilents’ ADS. Furthermore, we show how the large signal behavior in terms of convergence speed, time and region can be improved significantly. All methods proposed can be used for any kind of non-linear model, either analytical equations based or even table interpolated ones. I...

2011
Rodda Shobha Rani B. Jyothi

We proposed voltage-sourced converter (VSC) with Pulse-width modulation (PWM) provides a faster control that is required for flicker mitigation purpose. The voltage regulation in the distribution feeder is improved by installing a shunt compensator. The proposed DSTATCOM is modeled and its performance is simulated and verified for power factor correction and voltage regulation along with neutra...

Journal: :IEEE Trans. VLSI Syst. 2003
Joong-Seok Moon William C. Athas Sigfrid D. Soli Jeffrey T. Draper Peter A. Beerel

We describe a new design technique for efficient harmonic resonant rail drivers. The proposed circuit implementation is coupled to a standard pulse source and uses only discrete passive components and no external dc power supply. It can thus be externally tuned to minimize the consumed power in the target IC. A new design technique based on current-fed voltage pulse-forming network theory is pr...

2012
John George

Modern power system networks use active power filters for compensation of harmonic currents generated by non linear loads. In this paper a new method for generating reference currents for harmonic and reactive power compensation is proposed. The proposed method has the advantage that it generates the reference currents irrespective of the supply voltage and load conditions. So the source has to...

2012
S Ramana Kumar Joga Durga Prasad

Three-Phase four-wire distribution systems are facing severe power quality problems such as poor voltage regulation, high reactive power and harmonics current burden, load unbalancing, excessive neutral current, etc.This creates excessive neutral current both of fundamental and harmonic frequency and the neutral conductor gets overloaded. By integrating phase shifting into an extremely low zero...

2006
A. A. Latheef V. J. Gosbell V. Smith

The number of installations of photovoltaic solar panels and associated inverter systems within residential premises is increasing. As these systems incorporate a power electronics front end, they will have an influence on the quality of supply in regards to voltage harmonics. This paper investigates the harmonic impact on an 11kV distribution system due to the installation of residential type ...

2016
G S Mahesh

The harmonic mitigation using shunt active filters are most widely used in industrial and commercial applications. In this paper a Multi-Level Inverter is considered as DSTATCOM to compensate harmonics. The mathematical modeling of the system and design of the controller using synchronous reference frame theory is also presented. The nonlinear load generally known as diode rectifier load and an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید