Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. Accurate beam profile measurements of such beams are crucial for a precise and effective treatment. In this work four different dosimetric methods have been used for profile measurements of three small 6 MV circular fields having diameters of 7.5, 15.0 and 30.0 mm. A small sensitive v...
Background: Some ssues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calcula on in order to achieve an accurate dose delivery. Dose verifica on in complex radia on therapy techniques, such as intensity‐modulated radia on therapy (IMRT) calls for volumetric, ssue equivalent and energy independent dosimeter. The purpose of this study i...
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and appli...
Modern radiotherapy techniques try to deliver the radiation dose by steep gradient. Protocols for these complex treatment delivery techniques are important and extremely sensitive to errors in treatment delivery. To minimize such errors, 3D dosimeters were developed as a relative method for improving dose monitoring and delivery. The aim of this study is to analyze the capability and drawbacks ...
Polymeric excipients are crucial ingredients in modern pills, increasing the therapeutic bioavailability, safety, stability, and accessibility of lifesaving products to combat diseases in developed and developing countries worldwide. Because many early-pipeline drugs are clinically intractable due to hydrophobicity and crystallinity, new solubilizing excipients can reposition successful and eve...
background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...
High-molecular gel containing capsulate thermo-chromic liquid crystal is made to visualize three-dimensional distribution of electromagnetic power absorption. A preliminary experiment is performed at frequency of 1.5GHz. As a result of the experiment, the three-dimensional distribution of electromagnetic power absorption is clearly visualized. The result shows that the gel can be used as a phan...