نتایج جستجو برای: external fixator
تعداد نتایج: 190631 فیلتر نتایج به سال:
UNLABELLED PURPOUSE OF THE STUDY: Pelvic ring fractures in the geriatric population are of increasing frequency. Often insufficiency fractures or occult fractures are described. With a classical injury mechanism the majority of these injuries are the result of a low energy trauma, typically a fall from standing or during walking.Clinically, many patients report immediate anterior groin pain but...
PURPOSE Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. METHODS R...
Very little is known about the influence of the mechanical environment on the healing of large segmental defects. This partly reflects the lack of standardised, well characterised technologies to enable such studies. Here we report the design, construction and characterisation of a novel external fixator for use in conjunction with rat femoral defects. This device not only imposes a predetermin...
The Ortho-SUV frame (OSF) is a novel hexapod circular external fixator which draws upon the innovation of the Ilizarov method and the advantages of hexapod construction in the three-dimensional control of bone segments. Stability of fixation is critical to the success or failure of an external circular fixator for fracture or osteotomy healing. In vitro biomechanical modelling study was perform...
This is a report of the experience we have gathered in the application of the pinless fixator in cases of tibial fracture with soft tissue damage. In the Berufsgenossenschaftlichen Unfallklinik Ludwigshafen (Clinic for Trauma Surgery) 12 diaphyseal fractures of the tibia were stabilized with the pinless fixator in 1991. In all cases, conversion to an intramedullary nail was intended from the ve...
Objectives. The aim of the study was to investigate the results of patients with isolated length discrepancy between ulna and radius who underwent distraction osteogenesis with unilateral external fixator. Material and Methods. A patient with ulna shortening due to multiple enchondromatosis, a patient with ulna shortening due to ulnar club hand, and a patient with radial shortening due to radia...
A 50-year-old man presented with severe back pain and tenderness throughout the lumbar area after falling from a ladder. He had an unstable type-B burst fracture, with a spinal canal narrowing of 36% and an anterior height loss of 65%. His lower-limb neurological function was intact. An Ilizarov external spinal fixator was used; the pedicular half pins were inserted into the bilateral T11, T12,...
The aim of this study was to evaluate the effectiveness of unilateral external fixator as primary and definitive treatment for open tibial fractures, fractures with severe soft tissues injuries, threatened compartment syndrome, and in multiply injured patients. Two hundred and twenty-three tibial shaft fractures (212 patients) were treated. In open fractures, union was achieved in 25 weeks, whi...
Pin-tract infection (PTI) is the most commonly expected problem, or even an almost inevitable complication, when using external fixation. Left unteated, PTI will progress unavoidably, lead to mechanical pin loosening, and ultimately cause instability of the external fixator pin-bone construct. Thus, PTI remains a clinical challenge, specifically in cases of limb lengthening or deformity correct...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید