نتایج جستجو برای: epanet
تعداد نتایج: 226 فیلتر نتایج به سال:
PERUMDA Air Minum Tirta Khatulistiwa distributes clean water in Pontianak Barat District. Services are divided into several zones, one of which is zone H includes Pal Lima Village and Sungai Beliung Village. only 63.82% the population served with a pumping capacity 100 liters/second, based on this data, service not optimal. Population growth results lack at peak hours, so it necessary to analyz...
Abstract Water is one of the most invaluable resource and has many uses for human life. Managing water become more critical concern sustainability problems. One issues in rural drinking increasing demand. so it important to make planning network fulfil The purpose research plan good correct raw order meet needs people Kampung Bate their daily clean Demand Bate. method used this study use manual...
This paper proposes an optimized, gravity-looped water network for tented camps as a replacement of the trucking method, which depends on conveying from resource to tanks set up within by trucks, allowing people carry through containers their tent; this method is used supply live in with when providing cannot be met other ways. The
 cost installing minimized using Linear Programming select...
Abstract In this paper, information entropy was proposed to measure water quality reliability in a distribution system (WDS), which had been applied evaluate hydraulic the WDS. evaluation, residual chlorine is representative of quality, and first-order decay model usually adopted. The (R) based on (WQE) improved (Rd) (IWQE) were compared for three networks. method developed EPANET toolkit MATLA...
This paper presents a case study of the operational management Robinvale high-pressure piped irrigation water delivery system (RVHPS) in Australia. Based on datasets available, improved pump setpoint selection using calibrated hydraulic model is investigated. The first step was to implement pre-processing measured flow and pressure data identify errors possible faulty sensors. An EPANET simulat...
carefully considered to ensure that the water demand of students and staff can be met effectively efficiently. Calculations show a 0.35 m3/min is required, various existing pipe diameters are used, ranging from 65mm for main pipes, 60mm 50mm header 40mm, 32mm, 30mm, 25mm, 20mm, 15mm shaft pipes. However, after controlling velocity values using Epanet software, it was found some pipes had below ...
Optimizing pump operations is a challenging task for real-time management of water distribution systems (WDS). With suitable scheduling, pumping costs can be significantly reduced. In this research, novel economic model predictive control (EMPC) framework WDS proposed. Optimal are selected based on predicted system behavior over receding time horizon with the aim to minimize total energy cost. ...
Abstrak
 Penelitian ini bertujuan untuk mengetahui besar kebutuhan air dan sistem jaringan perpipaan Kecamatan Kota Atambua 20 tahun mendatang. Tahapan analisis yang dilakukan yaitu memproyeksi jumlah penduduk, fasilitas, menghitung air, membandingkan ketersediaannya menentukan pembagian pemenuhan serta melakukan simulasi menggunakan Software Epanet 2.0. Hasil harian maksimum tiap keluraha...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید