2011
Indra J. Das Minsong Cao Chee‐Wai Cheng Vladimir Misic Klaus Scheuring Edmund Schüle Peter A.S. Johnstone

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial 'EPID QC' phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm³ is used for EPID QA. This device ha...

Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...

Journal: :Medical physics 2010
Sean L Berry Cynthia S Polvorosa Cheng-Shie Wuu

PURPOSE Portal dose images acquired with an amorphous silicon electronic portal imaging device (EPID) suffer from artifacts related to backscattered radiation. The backscatter signal varies as a function of field size (FS) and location on the EPID. Most current portal dosimetry algorithms fail to account for the FS dependence. The ramifications of this omission are investigated and solutions fo...

Journal: :Medical physics 2006
Markus Wendling Robert J W Louwe Leah N McDermott Jan-Jakob Sonke Marcel van Herk Ben J Mijnheer

The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous silicon EPID. By using this back-projection algorithm, two-dimensional dose distr...

Journal: :Physics in medicine and biology 2011
Youcef El-Mohri Larry E Antonuk Qihua Zhao Richard B Choroszucha Hao Jiang Langechuan Liu

Megavoltage, cone-beam computed tomography (MV CBCT) employing an electronic portal imaging device (EPID) is a highly promising technique for providing soft-tissue visualization in image-guided radiotherapy. However, current EPIDs based on active matrix flat-panel imagers (AMFPIs), which are regarded as the gold standard for portal imaging and referred to as conventional MV AMFPIs, require high...

Amin Asgharzadeh Alvar Hanie Ghaempanah, Mohammad Reza Deevband, Mohsen Najafi

Introduction: In order to reduce patient setup error in treatment field, portal images with treatment beam (megavoltage x-ray) are widely used. These images are acquired by electronic portal imaging devices (EPID). However, portal images suffer from insufficient anatomical information, contrast, and spatial resolution, because of the fact that Compton scatter is the main photon...

Journal: :iranian journal of radiology 0
firoozeh ahmadi department of reproductive imaging at reproductive biomedicine research center, royan institute for reproductive biomedicine, acecr, tehran, iran; department of reproductive imaging at reproductive biomedicine research center, royan institute for reproductive biomedicine, acecr, p. o. box: 16635-148, tehran, iran. tel: +98-2123562446 hadieh haghighi department of reproductive imaging at reproductive biomedicine research center, royan institute for reproductive biomedicine, acecr, tehran, iran