نتایج جستجو برای: ejector refrigeration system

تعداد نتایج: 2234378  

Journal: :Canadian Anaesthetists' Society journal 1984
J Waaben M M Brinkløv S Jørgensen

The wide-range ejector flowmeter is an active scavenging system applying calibrated gas removal directly to the anaesthetic circuit. The evacuation rate can be adjusted on the flowmeter under visual control using the calibration scale ranging from 200 ml X min-1 to 151 X min-1. The accuracy of the calibration was tested on three ejector flowmeters at 12 different presettings. The percentage dev...

Journal: :Energy 2021

This paper presents the simulations and experiments for development of a hybrid reversible mobile air conditioning, organic Rankine cycle (ORC), ejector refrigeration (ERC) system. flexible compact system may be solution to introduction waste heat recovery in passenger cars. The fuel economy is calculated series electric vehicles (SHEVs). A global vehicle model used simulate annual weather cond...

In this work, a novel dual-nozzle ejector enhanced triple-evaporator refrigeration cycle (DETRC) without separator is proposed to improve the performance of the conventional ejector one (CETRC). The performance of DETRC is analyzed and compared with CETRC in term of energy coefficient of performance (COPen). Under given operating conditions, the COPen improvement of the no...

Journal: :gas processing 0
seyed mostafa mousavi naeynian department of mechanical engineering, k. n. toosi university of technology majid amidpour department of mechanical engineering, k. n. toosi university of technology meysam kamalinezhad department of mechanical engineering, k. n. toosi university of technology

â liquefied natural gas (lng) is the most economical way of transporting natural gas (ng) over long distances. liquefaction of ng by using vapor compression refrigeration system requires high operating and capital cost. due to lack of systematic design methods for multistage refrigeration cycles, the conventional approaches of determining optimal cycle configuration are mostly based on trial-an...

In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...

1997
M. J. Carletti

Abstract The following work documents the effect of streamwise vortices generated at the nozzle exit of an axisymmetric air jet on the amount of mass entrained into an ejector. In an experimental analysis of the mass entrainment of circular jet ejectors, we found that the introduction of half delta wing vortex generators in the exit of the jet nozzle (Reynolds number of 50,000) increased the am...

2011
M. Dennis

In recent times, there has been a rise in popularity of comfort cooling systems, mainly based on electrically driven heat pumps. The accompanying peak loading on electricity grids is proving to be particularly problematic and expensive for electricity utilities, notwithstanding the greenhouse gas emissions associated with the electricity consumption of these het pumps. An alternative is to gene...