نتایج جستجو برای: ebt3 radiochromic film

تعداد نتایج: 91084  

2015
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Kouichi Yabunaka

Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic ...

Journal: :Physics in medicine and biology 2002
Martin J Butson Peter K N Yu Tsang Cheung Peter Metcalfe

This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the...

Journal: :Applied sciences 2021

Radiochromic films are mainly used for two-dimensional dose verification in photon, electron, and proton therapy treatments. Moreover, the radiochromic film types available today allow their use a wide range, corresponding to applications from low-medical diagnostics high-dose beam profile measurements charged particle medical accelerators. An in-depth knowledge of characteristics films, operat...

2011
Jean‐François Aubry Hugo Bouchard Igor Bessières Frédéric Lacroix

The purpose of this study is to validate Eclipse's electron Monte Carlo algorithm (eMC) in heterogeneous phantoms using radiochromic films and EGSnrc as a reference Monte Carlo algorithm. Four heterogeneous phantoms are used in this study. Radiochromic films are inserted in these phantoms, including in heterogeneous media, and the measured relative dose distributions are compared to eMC calcula...

2002
Nobuteru NARIYAMA Yoshihito NAMITO Syuichi BAN

Introduction Recently, owing to the increase of synchrotron radiation facilities such as SPring-8, dose measurements of high-intense low-energy photons are increasingly needed for radiation protection and medical researches. For the dose measurement, tissue equivalence of dosimeter material becomes important. A radiochromic film that has sensitivity in the dose region of several Gy to 100 Gy ha...

2013
K Jordan

This review covers papers from the previous two years not being represented at this conference. Optically stimulated luminescence detectors, diamond detectors and radiochromic film are the major topics. An effort to link these papers to 3D dosimetry is included in this brief report. An overall theme of linear, water equivalent response is seen throughout the topics included.

2017
Nigel D Middlebrook Bess Sutherland Tanya Kairn

The dosimetric leaf gap (DLG) is a beam configuration parameter used in the Varian Eclipse treatment planning system, to model the effects of rounded MLC leaf ends. Measuring the DLG using the conventional sliding-slit technique has been shown to be produce questionable results for some volumetric modulated arc therapy (VMAT) treatments. This study therefore investigated the use of radiochromic...

2018
Jaeman Son Se Byeong Lee Youngkyung Lim Sung Yong Park Kwanho Cho Myonggeun Yoon Dong Ho Shin

This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam moni...

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2014

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید