نتایج جستجو برای: dosimetric parameters

تعداد نتایج: 583178  

2015
Jaeman Son Taesung Baek Boram Lee Dongho Shin Sung Yong Park Jeonghoon Park Young Kyung Lim Se Byeong Lee Jooyoung Kim Myonggeun Yoon

BACKGROUND This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. MATERIALS AND METHODS Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film,...

Journal: :journal of medical signals and sensors 0
mohammad-taghi bahreyni-toosi shahrokh nasseri mahdi momennezhad fatemeh hasanabadi hamid gholamhosseinian

the aim of this study is to provide a control software system, based on monte carlo simulation, and calculations of dosimetric parameters of standard and wedge radiation fi elds, using a monte carlo method. gate version 6.1 (opengate collaboration), was used to simulate a compact 6 mv linear accelerator system. in order to accelerate the calculations, the phase-space technique and cluster compu...

Journal: :International braz j urol : official journal of the Brazilian Society of Urology 2009
Carlos A S Franca Sergio L Vieira Antonio C P Carvalho Antonio J S Bernabe Antonio B R Penna

OBJECTIVES To assess the incidence and clinical parameters that could influence migration of seeds in localized prostate cancer patients treated by stranded versus loose sources by Iodine-125 brachytherapy. MATERIALS AND METHODS 100 patients were treated from January/1998 until December/2006. Age, PSA, clinical stage, Gleason, prostate volume, number of seeds, activity of radioactive seeds, a...

ژورنال: سنجش و ایمنی پرتو 2017

Radioactive 125I and 192Ir seeds are widely used as sources for interstitial implantation.192Ir is one of the important sources frequently used in brachytherapy. Up to now, different commercial models of this source type have been introduced to the clinical radiation oncology applications. The aim of the present study is to determine the dosimetric parameters of this new PDR Ir-192 source model...

Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...

Journal: :Radiation oncology 2018
Abdulhamid Chaikh Jarkko Ojala Catherine Khamphan Robin Garcia Jean Yves Giraud Juliette Thariat Jacques Balosso

BACKGROUND For a given prescribed dose of radiotherapy, with the successive generations of dose calculation algorithms, more monitor units (MUs) are generally needed. This is due to the implementation of successive improvements in dose calculation: better heterogeneity correction and more accurate estimation of secondary electron transport contribution. More recently, there is the possibility t...

2013
N. Gopishankar S. Vivekanandhan G.K. Rath M.A. Laviraj S. Senthilkumaran S.S. Kale S. Thulkar R.K. Bisht V. Subramani

The purpose of this study was to validate the newly designed acrylic phantom for routine dosimetric purpose in radiotherapy. The phantom can be used to evaluate and compare the calculated dose and measured dose using film and gel dosimetric methods. In this study, a doughnut-shaped planning target volume (8.54 cm3) and inner organ at risk (0.353 cm3) were delineated for an IMRT test plan using ...

2012
Mohammad Taghi Bahreyni Toossi Mahdi Ghorbani Ali Asghar Mowlavi Ali Soleimani Meigooni

BACKGROUND Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution...

2016
Elton Trigo Teixeira Leite Rafael Tsuneki Ugino Marco Antônio Santana Denis Vasconcelos Ferreira Maurício Russo Lopes Edilson Lopes Pelosi João Luis Fernandes da Silva Heloisa de Andrade Carvalho

OBJECTIVE To evaluate incidental irradiation of the internal mammary lymph nodes (IMLNs) through opposed tangential fields with conventional two-dimensional (2D) or three-dimensional (3D) radiotherapy techniques and to compare the results between the two techniques. MATERIALS AND METHODS This was a retrospective study of 80 breast cancer patients in whom radiotherapy of the IMLNs was not indi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید