background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...
introduction: radioiodine therapy is an effective method for treating thyroid cancer carcinoma, but it has some affects on normal tissues, hence dosimetry of vital organs are important to weigh the risks and benefits of this method. the aim of this study is to measure the absorbed doses of important organs by mcnp (monte carlo n particle) simulation and comparing the results of different method...
Low dose rate brachytherapy is a widely used modality for the treatment of prostate cancer. Most clinical treatment planning systems currently in use approximate all tissue to water, neglecting the existence of inhomogeneities, such as calcifications. The presence of prostatic calcifications may perturb the dose due to the higher photoelectric effect cross section in comparison to water. This s...
Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing.
PURPOSE Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not...
Finding accurate methods to be employed for the treatment of esophageal cancers is of especial interest for researchers, due to the sensitivity of this tissue. Recently radioactive stents loaded with I-125 brachytherapy seeds have been widely investigated for the treatment of advanced esophageal cancer. It is necessary to investigate the dose distribution of any radioactive esophageal stents be...
PURPOSE The clinical use of brachytherapy sources requires the existence of dosimetric data with enough of quality for the proper application of treatments in clinical practice. It has been found that the published data for the low dose rate CSM11 Cs-137 source lacks of smoothness in some regions because the data are too noisy. The purpose of this study was to calculate the dosimetric data for ...
The aim of this study is to provide a control software system, based on Monte Carlo simulation, and calculations of dosimetric parameters of standard and wedge radiation fields, using a Monte Carlo method. GATE version 6.1 (OpenGATE Collaboration), was used to simulate a compact 6 MV linear accelerator system. In order to accelerate the calculations, the phase-space technique and cluster comput...
تعیین مکان و اندازه بهینه منابع تولید پراکنده (dgs) در سیستم های توزیع برای کسب ماکزیمم منافع بالقوه با اهمیت می باشد. در این پایان نامه یک طراحی چند هدفه برای تعیین مکان و اندازه منابع dg در شبکه های توزیع موجود مبتنی بر روش ipso-monte carlo ارائه شده است. اهداف شامل مینیمم کردن تلفات اکتیو و راکتیو، بهبود پروفایل ولتاژ و بهبود قابلیت اطمینان سیستم های توزیع می باشد. تکنیک بکار رفته مبتنی بر ا...