نتایج جستجو برای: cr 39 dosimeter

تعداد نتایج: 143712  

Journal: :Journal of Nuclear Science and Technology 1991

2013
Mukhtar Ahmed Rana Gul Sher Shahid Manzoor Fariha Malik Kanwal Naz

The potential of the high resolution nuclear track detector (NTD) CR-39 is examined carefully for the measurement of relativistic nuclear projectile fragmentation cross sections and studies of related processes using the experience of many years of such measurements. The charge resolution and the charge resolving power of CR-39 detectors for the measurements of 158 A GeV Pb projectiles and thei...

2013
Dong Wook Kim Weon Kuu Chung Jungwook Shin Young Kyung Lim Dongho Shin Se Byeong Lee Myongguen Yoon Sung-Yong Park Dong Oh Shin Jung Keun Cho

BACKGROUND We measured and assessed ways to reduce the secondary neutron dose from a system for proton eye treatment. METHODS Proton beams of 60.30 MeV were delivered through an eye-treatment snout in passive scattering mode. Allyl diglycol carbonate (CR-39) etch detectors were used to measure the neutron dose in the external field at 0.00, 1.64, and 6.00 cm depths in a water phantom. Seconda...

2004
Heinrich Hora

For summarizing theoretical papers of the ICCF9 conference, a short reminder should be given about some significant experimental results that can form a basis for a theory of low energy nuclear reactions (LENR). For a more historic view, the motivation for the Fleischmann-Pons experiment or the Preparata effect were well explained while-as an unusual view-L. Case reported that experiments may b...

2005
A. G. LIPSON

Using noiseless solid-state CR-39 plastic track and Al2O3:C thermo-luminescent detectors, the yields of 3.0 MeV protons from DD-reaction and soft x-ray photons emitted from the cathode were studied in the periodic pulsing deuterium glow discharge with titanium cathodes at low discharge voltages (in the range 0.8–2.5 kV) and high current density (300–600 mA/cm2). The analysis of DD-proton yield ...

2008
Tibor Kovács Norbert Kávási Csaba Németh János Somlai Tamás Vigh Gábor Szeiler Shinji Tokonami Hiroyuki Takahashi

In this study a comparative integrating radon (Rn) and thoron (Rn) survey executed at underground workplaces are discussed. Two types of solid state nuclear track detectors (Radopot and Raduet) were applied for survey at four sites: a manganese mine, a bauxite mine, a tourist cave and a hospital cave. Several numbers of detecting points were chosen at each site and 1-1 Raduet and Radopot detect...

2003
C.W.Y. Yip J.P.Y. Ho D. Nikezic K. N. Yu

Solid state nuclear track detectors are commonly used for measurements of concentrations of radon gas and/or radon progeny. All these measurements depend critically on the thickness of the removed layer during etching. However, the thickness of removed layer calculated using the etching period does not necessarily provide a su7ciently accurate measure of the thickness. For example, the bulk etc...

2003
R. A. Oriani J. C. Fisher

By the use of Cr-39 particle track detectors immersed in the electrolyte, we confirm that a nuclear reaction of as-yet unknown nature can take place during electrolysis. With Li2SO4 dissolved in D2O or H2O and either Pd or Ni as cathodes, a very large statistical difference in nuclear track generation is found between detector chips immersed during electrolysis and the control chips immersed in...

2017
Shih-Ming Hsu Chao-Hsiung Hung Yi-Jen Liao Hsiao-Mei Fu Jo-Ting Tsai Yung-Hui Huang David Y. C. Huang

CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotolumines...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید