نتایج جستجو برای: coriolis mass flow meter

تعداد نتایج: 954173  

Journal: :Journal of Industrial & Engineering Chemistry 1919

2014

This application note gives an overview of different control mechanisms for MEMS Coriolis Vibratory Gyroscopes (CVG) and how they are implemented using the commercial off-the-shelf HF2LI Lock-in Amplifier. A MEMS gyroscope is a micro-machined inertial device that can measure the angle of orientation or the angular rate of rotation. The principle relies on a vibrating structure that is suspended...

Journal: :The European respiratory journal 1990
C P van Schayck E Dompeling C van Weel H Folgering H J van den Hoogen

The variability of peak flow measurements was studied in 24 patients with airway obstruction, using 12 Assess peak flow meters and a Fleisch pneumotachograph type 4 as a standard. The Assess peak flow meter gave systematic under-readings of 19-34% (low accuracy). The value scale of the Assess peak flow meter should be adjusted. As systematic under-readings do not influence the variability in pe...

2005
A. FRONEK V. GANZ

BLOOD flow in single vessels can be measured by direct methods such as rotameter, drop-flow meter, Rein-thermostromuhr, Venturi principle, electromagnetic flow meter and bubble-floAV meter. Such methods are usually characterized by great accuracy, but their applicability is considerably limited in man by the fact that the appropriate vessel must be made accessible. Blood flow in some regions wa...

2010
KOZO YOSHIDA

_ __--_---.--_--_-_---__--_________________ Introduction.______________________________________ Acknowledgment__________________________________ Water circulation.__________________________________ Latitudinal variation of isobaric topographies. _____ Horizontal current systems at various depths___--_Current at surface or near surface___________ Current at middepth levels_________________ Curre...

2015
Y. Zhao G. Lucas T. Leeungculsatien

Electromagnetic flow meters based on the principles of Faraday’s laws of induction have been used successfully in many industries. The conventional electromagnetic flow meter can measure the mean liquid velocity in axisymmetric single phase flows. However, in order to achieve velocity profile measurements in single phase flows with non-uniform velocity profiles, a novel Imaging Electromagnetic ...

Journal: :Respiratory care 2012
William R Howard

Achieving a stable blood oxygen level in patients who depend on this level of care is arguably determined in part by precise regulation of oxygen flow. The reliance on flow meter accuracy is the cautionary message that is relayed in the paper by Davidson et al in this issue of RESPIRATORY CARE.1 There is limited evidence that defends oxygen flow meter accuracy,2 which may account for the lack o...

Mohammad Esmail Khorasani Ferdavani Mohammad Javad Shiekhdavoodi Seyyed Majid Sajjadiyeh Zahra Noorghadami,

Objective: Drying is one of the most important post-harvesting processes in agriculture. Drying method and also drying time have an important effect on the amount of energy required. In this study analysis of energy consumption for drying corn in dryer reservoir with flow of warm air and the effect of the temperature and height of product layer on the amount of energy consumption per unit mass ...

2016
H. A. M. Hasan G. P. Lucas

Annular gas-liquid two phase flow is widely encountered in the nuclear industry. Various combinations of techniques have been employed in annular gas-liquid two phase flows to measure the flow parameters (e.g. liquid film thickness, gas volume fraction and the phase flow rates). One of the most useful techniques which has proven attractive for many multiphase flow applications is the electrical...

Journal: :European Journal of Mechanics - B/Fluids 2013

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید