Journal: :Computer methods and programs in biomedicine 2012
Mónica Abella Juan José Vaquero Alejandro Sisniega Javier Pascau Á. Udías V. García I. Vidal Manuel Desco

Most small-animal X-ray computed tomography (CT) scanners are based on cone-beam geometry with a flat-panel detector orbiting in a circular trajectory. Image reconstruction in these systems is usually performed by approximate methods based on the algorithm proposed by Feldkamp et al. (FDK). Besides the implementation of the reconstruction algorithm itself, in order to design a real system it is...

Journal: :dental research journal 0
mahnaz sheikhi mansour dakhil-alian zahra bahreinian

background: providing a cross-sectional image is essential for preimplant assessments. computed tomography (ct) and cone beam ct (cbct) images are very expensive and provide high radiation dose. tangential projection is a very simple, available, and low-dose technique that can be used in the anterior portion of mandible. the purpose of this study was to evaluate the accuracy of tangential proje...

Journal: :Medical physics 2004
Seung Wook Lee Ge Wang

Currently, cone-beam computerized tomography (CT) and micro-CT scanners are under rapid development for major biomedical applications. Half-scan cone-beam image reconstruction algorithms assume only part of a scanning turn, and are advantageous in terms of temporal resolution and image artifacts. While the existing half-scan cone-beam algorithms are in the Feldkamp framework, we have published ...

2004
KAI ZENG ZHIQIANG CHEN

Long-object problem and short-object problem both deal with reconstruction problems with truncated conebeam CT projections acquired with a helical path. They have significantly less practical limitations than original exact cone-beam CT reconstruction algorithms which the cone-beam must cover the whole object. The short-object problem can be defined as reconstruction of the whole object having ...

Journal: :Medical physics 2005
Youngbin Cho Douglas J Moseley Jeffrey H Siewerdsen David A Jaffray

Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a set of parameters that describes the geometry of such systems, and is essential...

2013
Emil Y. Sidky Rick Chartrand Jakob S. Jørgensen Xiaochuan Pan

A nonconvex optimization algorithm is developed, which exploits gradient magnitude image (GMI) sparsity for reduction in the projection view angle sampling rate. The algorithm shows greater potential for exploiting GMI sparsity than can be obtained by convex total variation (TV) based optimization. The nonconvex algorithm is demonstrated in simulation with ideal, noiseless data for a 2D fan-bea...

Journal: :Physics in medicine and biology 2005
Hengyong Yu Yangbo Ye Shiying Zhao Ge Wang

For applications in bolus-chasing computed tomography (CT) angiography and electron-beam micro-CT, the backprojection-filtration (BPF) formula developed by Zou and Pan was recently generalized by Ye et al to reconstruct images from cone-beam data collected along a rather flexible scanning locus, including a nonstandard spiral. A major implication of the generalized BPF formula is that it can be...