نتایج جستجو برای: composite steel plate shear walls
تعداد نتایج: 366721 فیلتر نتایج به سال:
Composite steel/concrete beams may buckle in hogging bending regions. As the top flange of I-beam in that arrangement is restricted from any translational deformation and twist, the web will distort during buckling presenting a phenomenon often described as restricted distortional buckling. There are limited studies available in the literature of restricted distortional buckling of composite st...
Steel frame with steel plate shear walls (SPSWs) is used to resist lateral loads caused by wind and earthquakes in high-rise buildings. In this load-resisting system, the cost performance are more efficient than moment system. Behaviors of beam-to-column connections assumed be pinned or fixed simplify calculation past few decades. However, studies have stated that such a simulation fails reveal...
Steel plates in double skin composite (DSC) panels are restrained by a concrete core and welded stud shear connectors at discrete positions. Local buckling of steel plates in DSC panels may occur in a unilateral mode between stud shear connectors when subjected to combined states of stresses. This paper studies the local and post-local buckling strength of steel plates in DSC panels under biaxi...
Steel Plate Shear Walls (SPSWs), which consist of infill steel panels surrounded by columns, called Vertical Boundary Elements (VBEs), and beams, called Horizontal Boundary Elements (HBEs), are rapidly becoming an appealing alternative lateral force resisting system for building structures in the United States, Canada, Mexico, Japan, Taiwan and other countries. This paper presents results of so...
Design requirements now appear in the 2005 AISC Seismic Provisions for Structural Steel Buildings (AISC, 2005b), referred to herein as The Provisions, for steel plate shear walls (SPSWs) that are designed such that their web plates buckle in shear and develop diagonal tension fi eld action when resisting lateral loads. Energy dissipation and ductility during seismic events is principally achiev...
The behavior of steel-concrete composite beams is strongly influenced by the type of shear connection between the steel beam and the concrete slab. For accurate analytical predictions, the structural model must account for the interlayer slip between these two components. In numerous engineering applications e.g., in the fields of structural optimization, structural reliability analysis, and fi...
This paper describes the mitigation of shaped charge penetration of steel armour by the use of spaced metallic and composite plates. The target consisted of one or more steel plates of 10mm thickness some of which were backed by 25mm E-glass polyester composite panels at various additional spacings from the rearmost steel plate. A 32mm diameter shaped charge warhead was detonated at a standoff ...
نمودار تعداد نتایج جستجو در هر سال