نتایج جستجو برای: calibration

تعداد نتایج: 56280  

2011
Sanna Kaasalainen Ulla Pyysalo Anssi Krooks Ants Vain Antero Kukko Juha Hyyppä Mikko Kaasalainen

Radiometric calibration of airborne laser scanning (ALS) intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calib...

2014
Pankaj Garg Sukhwinder Singh

This paper presents a comparative evaluation of liquid-crystal display (LCDs) and cathode-ray tube (CRT) displays from a color-rendition and color-calibration perspective. Common display calibration models and assumptions are reviewed and their applicability to LCDs and CRTs is evaluated through an experimental study. The displays are compared with respect to the color-calibration accuracy, eas...

1998
Scott W. Hadley L. Scott Johnson Charles A. Pelizzari

There has been recent interest in using video cameras along with computer vision and photogrammetric techniques to aid in the daily positioning of patients for radiation therapy. We describe here a method to calibrate video cameras to the beam coordinate system of a radiation therapy treatment machine. Standard camera calibration relates the threedimensional coordinate system of a calibration p...

2013
Jing Zou Xiao-Dong Hu Hanyu Lv Xiaotang Hu

The effects of calibration phantoms on the correction results of the empirical artifacts correction method (ECCU) for the case of tube modulation were investigated. To improve the validity of the ECCU method, the effect of the geometry parameter of a typical single-material calibration phantom (water calibration phantom) on the ECCU algorithm was investigated. Dual-material calibration phantoms...

2000
Klaus Veit Gerd Häusler

Metrical calibration is very critical for the accuracy of a 3d sensor. Measuring uncertainty of about 1:3000 of the z-range requires a calibration accuracy of about 1:10. Several model-based approaches for this problem exist. In this article the calibration task for a phase measuring triangulation sensor is described. After a short description of the geometrical distortions that are compensated...

Journal: :Ear and hearing 2013
Michal L Reuven Stephen T Neely Judy G Kopun Daniel M Rasetshwane Jont B Allen Hongyang Tan Michael P Gorga

OBJECTIVES Distortion-product otoacoustic emissions (DPOAEs) collected after sound pressure level (SPL) calibration are susceptible to standing waves that affect measurements at the plane of the probe microphone due to overlap of incident and reflected waves. These standing-wave effects can be as large as 20 dB, and may affect frequencies both above and below 4 kHz. It has been shown that forwa...

Journal: :international journal of environmental research 2012
e.m.m. zahran

the aim of this research paper is the introduction of a novel mathematical approach to improvethe accuracy of the results of air pollution dispersion models based on the calibration of input backgroundconcentrations. using the dunkirk area of the city of nottingham in the uk as a case study, an air pollutionmodel in adms-roads was created for developing the mathematical approach. the iterative ...

Journal: :iranian journal of economic studies 2014
ali hussein samadi ali hussein ostadzad

abstract the main purpose of this paper is to obtain the optimal amount of expenses of government relating to the protection of property rights (pprs). to achieve these purposes we have introduced concept of social intelligence with respect to pprs and then developed different growth model from existing literature. in the second step the optimal share of government spending on the pprs is calcu...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2014
shahram shoeibi iman moazzami goudarzi hossein rastegar behrouz janat nafiseh sadeghi

recently, with increasing public awareness of food safety, developments of some valid and rapidly analytical methods are required for the determination of residual pesticides in crops.this study was conducted on validation of a reliable, accurate and precise method for multi analysis of pesticides residue in melon as a main fruit in iranian food basket. a reliable, and valid method based on spi...

Journal: :international journal of civil engineering 0
kourosh behzadian abdollah ardeshir zoran kapelan dragan savic

a novel approach to determine optimal sampling locations under parameter uncertainty in a water distribution system (wds) for the purpose of its hydraulic model calibration is presented. the problem is formulated as a multi-objective optimisation problem under calibration parameter uncertainty. the objectives are to maximise the calibrated model accuracy and to minimise the number of sampling d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید