نتایج جستجو برای: atrial cardiac catheterization septal occluder device

تعداد نتایج: 1021095  

Journal: :Heart 2003
G Fischer J Stieh A Uebing U Hoffmann G Morf H H Kramer

AIM To evaluate the safety and efficacy of transcatheter closure of secundum atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS 236 consecutive patients with a significant ASD (age 6 months to 46 years, median 5 years; body weight 6.5-79 kg, median 18 kg) were considered for transcatheter closure with the Amplatzer septal occluder; 18 patients with defects that were too l...

Journal: :Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology 2017
Sílvia Aguiar Rosa Filipa Ferreira Lídia de Sousa António Fiarresga José Diogo Martins Ana Galrinho Ana Agapito Paula Fazendas Fátima F Pinto Rui Cruz Ferreira

A 39-year-old woman underwent uneventful percutaneous occlusion of an ostium secundum atrial septal defect (ASD) with a 22 mm Ultrasept ASD Occluder®. Transesophageal echocardiography (TEE) performed two years after implantation revealed a de novo residual left-to-right shunt through the correctly implanted device. Three-dimensional transesophageal echocardiography (3D TEE) further clarified th...

Journal: :Journal of the American College of Cardiology 1998
B D Thanopoulos C V Laskari G S Tsaousis A Zarayelyan A Vekiou G S Papadopoulos

OBJECTIVES This study reports our clinical experience with transcatheter closure of secundum atrial septal defects (ASDs) in children, using the Amplatzer, a new occlusion device. BACKGROUND None of the devices previously used for transcatheter closure of interatrial communications has gained wide acceptance. METHODS We examined the efficacy and safety of the Amplatzer, a new self-centering...

Journal: :Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2009
Stephen Brown Marc Gewillig

Percutaneous atrial septal defect closure is routinely performed nowadays because of the ease of implantation as well as the low complication rate. The Atriasept ASD occluder is a low profile, double disc device; over the years several modifications have been made. We report two cases of aortic sinus perforation by the Atriasept ASD occluder (model 2007). Two asymptomatic patients, in whom the ...

Journal: :Journal of Cardiothoracic Surgery 2021

Abstract Background Cardiac erosion after percutaneous atrial septal defect (ASD) closure is a rare complication that requires immediate life-saving emergency surgery. In this report, we present our successful strategy for cardiac arrest due to tamponade caused by 6 years the of an ASD. Case presentation The patient was 50-year-old man who received treatment using Amplatzer occluder (St. Jude M...

Journal: :Circulation 2001
E M Zahn N Wilson W Cutright L A Latson

BACKGROUND A variety of transcatheter atrial septal defect (ASD) occluders are currently in use around the world. Although for the most part effective, all of these devices lack features that would be desirable in a "perfect" device. The Helex septal occluder is a new type of device designed to improve the results of transcatheter ASD closure. This study was designed to examine the effectivenes...

2013
Sait Demirkol Sevket Balta Mustafa Cakar Ugur Kucuk

We read with great interest the article ‘‘Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder’’ written by Xi EP et al. (1). The authors aimed to report their experiences with three patients who underwent the percutaneous closure of a posttraumatic ventricular septal defect (VSD) with a patent ductus arteriosus (PDA) occluder. They conclud...

Journal: :The European respiratory journal 1994
E Frans C Timmermans M C Herregods H De Geest W Daenen M Delanote M Decramer

A patient with platypnoea after right pneumonectomy and radiotherapy is described. On transoesophageal contrast echocardiography and cardiac catheterization, an atrial septal aneurysm with interatrial right-to-left shunting was detected. Symptoms disappeared after surgical correction. To the best of our knowledge, this is the first report of a patient with a septal aneurysm and severe platypnoea.

Journal: :Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2013
Turkay Saritas Mehmet Gungor Kaya Yat Yin Lam Abdullah Erdem Celal Akdeniz Fadli Demir Nurdan Erol Halil Demir Ahmet Celebi

AIM We sought to investigate the safety and efficacy of Cardio-O-Fix septal occluder (CSO) in percutaneous closure of atrial septal defects (ASD) as compared to the Amplatzer septal occluder (ASO). METHODS A consecutive of 351 patients received transcatheter ASD closure with CSO or ASO from July 2004 to October 2010 were studied. The ASDs were divided into simple- (isolated defects <26 mm) or...

2010
Su Nam Kim Deok Young Choi

A 47-year-old male patient in whom atrial septal defect (ASD) had been diagnosed 15 years previously was admitted for cardiac catheterization. He had definite cyanotic lips and nail beds and severe pulmonary arterial hypertension (PAH). He had received medical treatment only for the last few years after being diagnosed with Eisenmenger syndrome. After cardiac catheterization, he received ilopro...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید