نتایج جستجو برای: asymmetric shaft

تعداد نتایج: 76410  

2008
F. Andrés Bejarano Jia Yi Frederick Just Rico

This paper presents a novel real-time crack identification method to determine the position and depth of a transverse open crack on a rotating shaft. A newly developed wireless sensor capable of being mounted directly on the shaft can be employed to monitor acceleration at different points of a shaft in a rotating coordinate system. The vibration parameters obtained from a Finite Element Model ...

Journal: :journal of dentistry, tehran university of medical sciences 0
allahyar geramy professor, dental research center dentistry research institute, department of orthodontics, tehran university of medical sciences, tehran, iran omid mortezai assistant professor of orthodontics, dental caries prevention research center, qazvin university of medical sciences, qazvin, iran masomeh esmaily assistant professor, department of orthodontics, lorestan university of medical sciences, khorramabad, iran hojat darvishpour postgraduate student, orthodontics department, school of dentistry, tehran university of medical sciences, tehran, iran

o bjectives: headgears are among the effective orthodontic appliances to achieve treatment goals. unilateral molar distal movement is sometimes needed during an orthodontic treat- ment, which can be achieved by an asymmetric headgear. different unilateral headgears have been introduced. the main goal of this study was to analyze the force system of uni- lateral expanded outer bow asymmetric hea...

Journal: :trauma monthly 0
ali akbar esmailiejah akhtar orthopedic hospital, shahid beheshti university of medical sciences, tehran, ir iran mohammad reza abbasian akhtar orthopedic hospital, shahid beheshti university of medical sciences, tehran, ir iran; akhtar orthopedic hospital, shahid beheshti university of medical sciences, tehran, ir iran. tel: +98-9121831752, fax: +98-2122606614 farshad safdari orthopedics research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, ir iran keyqobad ashoori orthopedics research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, ir iran

conclusions due to the shorter :union: time, to some extent less complication rate and comparable functional and clinical results, the authors recommend to use the mipo technique in treating the mid-distal humeral shaft fracture. results the median of :union: time was shorter in the mipo group (4 months versus 5 months). the time of surgery and functional outcomes based on the ucla and meps sco...

Journal: :Kathmandu University medical journal 2008
I Pradhan A K Banskota

Anterior dislocation of the shoulder joint with ipsilateral humerus shaft fracture is a very rare injury. Until July 2006 only 18 cases have been reported in the literature. Here we report a case of Anterior Shoulder dislocation with greater tuberosity and shaft of humerus fracture. The patient was treated by Open reduction and internal fixation of the shaft fracture followed by closed reductio...

Journal: :Journal of Ayub Medical College, Abbottabad : JAMC 2010
Mohammad Naeem-ur-Razaq Muhammad Qasim Shahid Sultan

BACKGROUND There are many ways to treat aseptic non-union of femoral shaft fractures with reported varied success rate. Amongst all these, Exchange nailing is the simplest and most successful technique for treating aseptic non union of femoral shaft fractures. We have carried out a prospective study in the Department of Trauma & Orthopaedics, Ayub Medical College Abbottabad to analyse the role ...

Journal: :Development 1999
J Kavaler W Fu H Duan M Noll J W Posakony

The adult peripheral nervous system of Drosophila includes a complex array of mechanosensory organs (bristles) that cover much of the body surface of the fly. The four cells (shaft, socket, sheath, and neuron) which compose each of these organs adopt distinct fates as a result of cell-cell signaling via the Notch (N) pathway. However, the specific mechanisms by which these cells execute their c...

2017
Swapna Nair Ramachandran Unnikrishnan Nair

BACKGROUND To study phacoemulsification probe shaft/wound and corneal surface/tip temperatures in vivo during longitudinal, torsional and combined phacoemulsification modes and their relationship to machine parameters. DESIGN This was a prospective study at Chaithanya Eye Hospital and Research Institute, Trivandrum, India (tertiary). PARTICIPANTS Twenty-two eyes of 22 patients were randomiz...

2014
Dominik Kujawa Tomasz Zawadzki

The paper presents a new approach to the parameter identification of a wind turbine shaft vibrations measured with piezoelectric sensor. The system order and unknown processes matrices are determined using the wind force as the model input and wind turbine shaft vibrations as the model output. The identified model can be used to estimate the shaft vibrations and design an early damage monitorin...

Journal: :The Journal of bone and joint surgery. British volume 1995
O M Böstman

We report the results of a three-year study of bifocal fractures of the tibia and fibula, excluding segmental shaft fractures. In our whole series, these formed 4.7% of all tibial diaphyseal fractures. We describe three groups: bifocal fractures of both the proximal and the distal joint surfaces, fractures of the shaft and tibial plateau, and fractures of the shaft and ankle. These groups of fr...

2011
Sasho James MacKenzie

Introduction This paper summarizes my collection of research findings on the role of shaft flexibility in the golf swing. The research was initiated during my PhD thesis under the supervision of Dr. Eric Sprigings. The goal was to gain a comprehensive understanding of the role that shaft stiffness plays in the golf swing. This paper will provide a rationale for the methodologies I’ve used, a su...

نمودار تعداد نتایج جستجو در هر سال