نتایج جستجو برای: application radiotherapy dosimetry

تعداد نتایج: 830352  

2013
Jie Qiu Zhikai Liu Bo Yang Xiaorong Hou Fuquan Zhang

BACKGROUND AND PURPOSE To present a novel helical TomoTherapy-based method for whole breast radiotherapy that has better dosimetry and also has acceptable low-dose regions for lungs, heart, and contralateral breast compared with tangential field-in-field IMRT (FIF-IMRT). MATERIAL AND METHODS Ten patients with left-side breast cancer were planned with low-dose-area-constrained helical TomoTher...

2013
B Mijnheer I Olaciregui-Ruiz R Rozendaal J-J Sonke H Spreeuw R Tielenburg M van Herk Antoni van Leeuwenhoek

In this paper the various approaches of EPID-based in vivo IMRT and VMAT dose verification, and their clinical implementation, are described. It will be shown that EPID-based in vivo dosimetry plays an important role in the total chain of verification procedures in a radiotherapy department. EPID-based dosimetry, in combination with in-room imaging, is a fast and accurate tool for 3D in vivo ve...

2015
F. Seif M. R. Bayatiani

BACKGROUND Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in optim...

2016
Juan López-Tarjuelo Virginia Morillo-Macías Ana Bouché-Babiloni Enrique Boldó-Roda Rafael Lozoya-Albacar Carlos Ferrer-Albiach

BACKGROUND Intraoperative electron radiotherapy (IOERT) is a highly selective radiotherapy technique which aims to treat restricted anatomic volumes during oncological surgery and is now the subject of intense re-evaluation. In vivo dosimetry has been recommended for IOERT and has been identified as a risk-reduction intervention in the context of an IOERT risk analysis. Despite reports of fruit...

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

Journal: :Sarcoma 2004
M. V. Williams N. G. Burnet E. Sherwin R. Kestelman A. R. Geater S. J. Thomas C. B. Wilson

Purpose. Following limb conserving surgery for bone or soft tissue sarcoma, patients may require post-operative radiotherapy to minimise the risk of local recurrence. In such circumstances the metal prosthesis reduces the dose in its shadow by approximately 10% when using opposed fields. We describe a technique to boost the underdosed area to overcome this problem.Patients or subjects. Seven se...

Journal: :Journal of Physics: Conference Series 2022

Abstract In vivo dosimetry for patient radioprotection is a real challenge concerning new radiotherapy treatments. this study we aim to develop dosimeter based on tissue equivalent material, flexible and adaptable the morphology in order perform complex irradiation beams. Here, report evaluation standard beams of highly composed silicone elastomer containing leucomalachite green as radiochromic...

2012
Stephen F. Kry Susan A. Smith Rita Weathers Marilyn Stovall

The skin dose associated with radiotherapy may be of interest for clinical evaluation or investigating the risk of late effects. However, skin dose is not intuitive and is difficult to measure. Our objectives were to develop and evaluate a general estimation technique for skin dose based on treatment parameters. The literature on skin dose was supplemented with measurements and Monte Carlo simu...

2008
Peter L. Roberson Jean M. Moran Ravi Kulasekere

Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید