نتایج جستجو برای: 3d film dosimetry dvh

تعداد نتایج: 284641  

2015
Gareth Polmeer

The works make the ‘present’ image from what is normally absent. The underlying structural principles of video frames and encoding are the bases of the developing picture. In this sense, the ‘now’ of a video image is multidimensional and variable; past, present and future are the simultaneous condition of a single moment (unlike film frames, which can be isolated as spatially and temporally dis...

H.A. Nedaie, Kh. Asnaashari, M. Allahverdi, M. Yarahmadi, O.A. Sauer,

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...

Journal: :Medical physics 2001
M Oldham J H Siewerdsen A Shetty D A Jaffray

The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that...

2012
Atsushi Komemushi Noboru Tanigawa Shuji Kariya Rie Yagi Miyuki Nakatani Satoshi Suzuki Akira Sano Koshi Ikeda Keita Utsunomiya Yoko Harima Satoshi Sawada

Purpose. To assess differences in dose distribution of a vertebral body injected with bone cement as calculated by radiation treatment planning system (RTPS) and actual dose distribution. Methods. We prepared two water-equivalent phantoms with cement, and the other two phantoms without cement. The bulk density of the bone cement was imported into RTPS to reduce error from high CT values. A dose...

2017
Masahide Saito Noriyuki Kadoya Kiyokazu Sato Kengo Ito Suguru Dobashi Ken Takeda Hiroshi Onishi Keiichi Jingu

The purpose of this study was comparing dose-volume histogram (DVH)-based plan verification methods for volumetric modulated arc therapy (VMAT) pretreatment QA. We evaluated two 3D dose reconstruction systems: ArcCHECK-3DVH system (Sun Nuclear corp.) and Varian dynalog-based dose reconstruction (DBDR) system, developed in-house. Fifteen prostate cancer patients (67.6 Gy/26 Fr), four head and ne...

Journal: :Journal of Applied Clinical Medical Physics 2012

Journal: :iranian journal of medical physics 0
keyvan jabbari department of medical physics and engineering, school of medicine, isfahan university of medical sciences, isfahan, iran

introduction intensity modulated radiation therapy (imrt) has made a significant progress in radiation therapy centers in recent years. in this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. considering the complexity of this method, the quality control for imrt is a topic of interest for researchers. this article is about the various ...

Journal: :iranian journal of radiation research 0
m. yarahmadi kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran kh. asnaashari department of radiotherapy , cancer institute, tehran university of medical sciences, tehran, iran o.a. sauer klinik und poliklinik für strahlentherapie, university of würzburg, josef-schneider-strasse 11, 97080 würzburg, germany

background: small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (imrt) and stereotactic radiosurgery (srs) treatments. accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. hence the ebt2 (external beam therapy) gafchromic film was used for dosimetry of sm...

Journal: :Radiotherapy and Oncology 2019

Journal: :Physics in medicine and biology 2007
R P Srivastava C De Wagter

Radiographic or silver halide film is a well-established 2D dosimeter with an unquestioned spatial resolution. But its higher sensitivity to low-energy photons has to be taken into consideration. Metal compensators or physical modulators to deliver intensity modulated radiation therapy (IMRT) are known to change the beam energy spectrum and to produce scattered photons and contaminating electro...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید