نتایج جستجو برای: 3 dimensionalfilm dosimetry tps heterogeneity

تعداد نتایج: 1901498  

2016
Alan Koay Surinder Khelae Koh Kok Wei Zulkeflee Muhammad Rosli Mohd Ali Razali Omar

Introduction One of the most feared complications of a traditional pacemaker system is cardiac implantable electronic device infection. In such cases, a complete removal of the entire system is recommended. With the advent of the leadless transcatheter pacemaker system (TPS), the weak link— namely, the pacing leads that contribute to this problem— can be ultimately eliminated. At least 2 major ...

2011
N. Anderson C. Lawford V. Khoo M. Rolfo D. Lim Joon M. Wada

Intensity-modulated radiotherapy (IMRT) has reduced the impact of acute and late toxicities associated with head and neck radiotherapy. Treatment planning system (TPS) advances in biological cost function based optimization (BBO) and improved segmentation techniques have increased organ at risk (OAR) sparing compared to conventional dose-based optimization (DBO). A planning study was undertaken...

2010
Vicente Carmona Jose Perez-Calatayud Françoise Lliso Jose Richart Facundo Ballester Mª Carmen Pujades-Claumarchirant Jack L.M. Venselaar

PURPOSE In this work a spreadsheet based program is presented that to a large extent independently verifies the calculations of individual plans of brachytherapy treatment planning systems for low dose rate, high dose rate and pulsed dose rate techniques. MATERIAL AND METHODS The verification program has been developed based on workbooks/spreadsheets. The treatment planning system output text...

Journal: :J. UCS 1999
Christoph Benzmüller Matthew Bishop Volker Sorge

This paper reports on the integration of the higher-order theorem proving environment Tps [Andrews et al., 1996] into the mathematical assistant mega [Benzm uller et al., 1997]. Tps can be called from mega either as a black box or as an interactive system. In black box mode, the user has control over the parameters which control proof search inTps; in interactive mode, all features of theTps-s...

2004
Xianhong Xie Moo K. Chung Grace Wahba

The segmentations by human, TPS method, and SPM method are given in Figure 3. The summary table for all the coefficients and indices is given in Table 1, which shows that the performance of TPS is similar to that of SPM by comparing against manual segmentation. Also, the TPS segmentations tend to have smaller variances than the SPM segmentations. The subpixel property of TPS method is shown in ...

2016
Moti R. Paudel Anthony Kim Arman Sarfehnia Sayed B. Ahmad David J. Beachey Arjun Sahgal Brian M. Keller

A new GPU-based Monte Carlo dose calculation algorithm (GPUMCD), devel-oped by the vendor Elekta for the Monaco treatment planning system (TPS), is capable of modeling dose for both a standard linear accelerator and an Elekta MRI linear accelerator. We have experimentally evaluated this algorithm for a standard Elekta Agility linear accelerator. A beam model was developed in the Monaco TPS (res...

2014
Christopher L. Nelson Bryan E. Mason Ronald C. Robinson Kelly D. Kisling Steven M. Kirsner

A dose calculation verification system (VS) was acquired and commissioned as a second check on the treatment planning system (TPS). This system reads DICOM CT datasets, RT plans, RT structures, and RT dose from the TPS and automatically, using its own collapsed cone superposition/convolution algorithm, computes dose on the same CT dataset. The system was commissioned by extracting basic beam pa...

2016
Alexandra Bourgouin Nicolas Varfalvy Louis Archambault

Out-of-field dose depends on multiple factors, making peripheral dosimetry com-plex. Only a few dosimeters have the required features for measuring peripheral dose. Plastic scintillator dosimeters (PSDs) offer numerous dosimetric advantages as required for out-of-field dosimetry. The purpose of this study is to determine the potential of using PSD as a surface peripheral dosimeter. Measurements...

2016
Jeroen B van de Kamer

In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید