نتایج جستجو برای: آشکارساز 39 cr

تعداد نتایج: 142907  

2003
R. A. Oriani J. C. Fisher

By the use of Cr-39 particle track detectors immersed in the electrolyte, we confirm that a nuclear reaction of as-yet unknown nature can take place during electrolysis. With Li2SO4 dissolved in D2O or H2O and either Pd or Ni as cathodes, a very large statistical difference in nuclear track generation is found between detector chips immersed during electrolysis and the control chips immersed in...

Journal: :International Journal Of Radiation Applications And Instrumentation. Part D, Nuclear Tracks And Radiation Measurements 1992
V E Dudkin E E Kovalev Y V Potapov E V Benton A L Frank E R Benton J W Watts T A Parnell E Schopper B Baican

Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the LET spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented....

2006
D. Nikezic C.W.Y. Yip S.Y.Y. Leung J.K.C. Leung K. N. Yu

The (CR–LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiment...

2009
S. Cecchini H. Dekhissi G. Giacomelli A. R. Margiotta

We present measurements of fragmentation cross sections of relativistic nuclei and upper limits for the production probability of nuclear fragments with fractional charge using CR39 nuclear track detectors and an automated scanning system. The measurements of the total and partial charge changing fragmentation cross sections concern 16 GeV/nucleon oxygen ions, 14.5 GeV/nucleon silicon ions and ...

2008
H. Al-Ghamdi Fazal-ur-Rehman M. I. Al-Jarallah N. Maalej

In X-ray radiotherapy accelerators, neutrons are produced mainly by ( , n) reaction when high energy X-rays interact with high Z materials of the linear accelerator head. These materials include the lead (Pb) used as shielding in the collimator, tungsten (W) target used for the production of X-rays and iron (Fe) in the accelerator head. These unwanted neutrons contaminate the therapeutic beam a...

2008
M. Spurio

We report the measurement of the fragmentation cross sections in high-energy nucleus-nucleus collisions using the 158 A GeV Pb82+ beam from the CERN-SPS. The fragments have charges changed from that of the incident projectile nucleus by ∆Z = ZPb − Zfrag, with 8 ≤ ∆Z < 75. The targets range from polyethylene to lead. Charge identification is made with CR39 nuclear track detectors, measured with ...

2013
Teruaki Konishi Masakazu Oikawa Noriyoshi Suya Takahiro Ishikawa Takeshi Maeda Alisa Kobayashi Naoko Shiomi Kumiko Kodama Tsuyoshi Hamano Shino Homma-Takeda Mayu Isono Kotaro Hieda Yukio Uchihori Yoshiyuki Shirakawa

The Single Particle Irradiation system to Cell (SPICE) facility at the National Institute of Radiological Sciences (NIRS) is a focused vertical microbeam system designed to irradiate the nuclei of adhesive mammalian cells with a defined number of 3.4 MeV protons. The approximately 2-μm diameter proton beam is focused with a magnetic quadrupole triplet lens and traverses the cells contained in d...

Journal: :Annals of oncology : official journal of the European Society for Medical Oncology 2010
P L Zinzani F Venturini V Stefoni M Fina C Pellegrini E Derenzini L Gandolfi A Broccoli L Argnani F Quirini S Pileri M Baccarani

BACKGROUND Peripheral T-cell lymphoma unspecified (PTCLU) and mycosis fungoides (MF) often show resistance to conventional chemotherapy. Gemcitabine should be considered a suitable option. We report the long-term update of 39 pretreated T-cell lymphoma patients treated with gemcitabine. PATIENTS AND METHODS From May 1997 to September 2007, 39 pretreated MF and PTCLU patients received gemcitab...

2010
D. Wertheim

It has been suggested that 3 to 5% of total lung cancer deaths in the UK may be associated with elevated radon concentration. Radon gas levels can be assessed using CR-39 plastic detectors which are often assessed by 2-D image analysis of surface images. 3-D analysis has the potential to provide information relating to the angle at which alpha particles impinge on the detector. In this study we...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید