نتایج جستجو برای: volumetric modulated arc therapy

تعداد نتایج: 761818  

Journal: :Practical radiation oncology 2014
Peng Dong Dan Nguyen Dan Ruan Christopher King Troy Long Edwin Romeijn Daniel A Low Patrick Kupelian Michael Steinberg Yingli Yang Ke Sheng

PURPOSE Significant dosimetric improvement for radiation therapy using optimized noncoplanar fields has been previously demonstrated. The purpose here is to study the feasibility of optimized robotic noncoplanar radiation therapy, termed 4π therapy, for prostate cancer treatments on a conventional C-arm linac. METHODS AND MATERIALS Twelve low-risk prostate cancer patients previously treated b...

2017
Hideharu Miura Shuichi Ozawa Yasushi Nagata

This study investigated position dependence in planning target volume (PTV)-based and robust optimization plans using full-arc and partial-arc volumetric modulated arc therapy (VMAT). The gantry angles at the periphery, intermediate, and center CTV positions were 181°-180° (full-arc VMAT) and 181°-360° (partial-arc VMAT). A PTV-based optimization plan was defined by 5 mm margin expansion of the...

Journal: :Medical physics 2012
David Craft Dualta McQuaid Jeremiah Wala Wei Chen Ehsan Salari Thomas Bortfeld

PURPOSE To make the planning of volumetric modulated arc therapy (VMAT) faster and to explore the tradeoffs between planning objectives and delivery efficiency. METHODS A convex multicriteria dose optimization problem is solved for an angular grid of 180 equi-spaced beams. This allows the planner to navigate the ideal dose distribution Pareto surface and select a plan of desired target covera...

2014
Pascal Hauri Sarah Verlaan Shaun Graydon Linda Ahnen Stephan Klöck Stephanie Lang

The Delta(4DVH) Anatomy 3D quality assurance (QA) system (ScandiDos), which converts the measured detector dose into the dose distribution in the patient geometry was evaluated. It allows a direct comparison of the calculated 3D dose with the measured back-projected dose. In total, 16 static and 16 volumetric-modulated arc therapy (VMAT) fields were planned using four different energies. Isocen...

Journal: :Medical physics 2012
Rasmus Bokrantz

PURPOSE To develop a method for inverse volumetric-modulated arc therapy (VMAT) planning that combines multicriteria optimization (MCO) with direct machine parameter optimization. The ultimate goal is to provide an efficient and intuitive method for generating high quality VMAT plans. METHODS Multicriteria radiation therapy treatment planning amounts to approximating the relevant treatment op...

2017
Jeffrey E. Snyder Ryan T. Flynn Daniel E. Hyer

The accurate delivery of respiratory-gated volumetric modulated arc therapy (VMAT) treatment plans presents a challenge since the gantry rotation and collimator leaves must be repeatedly stopped and set into motion during each breathing cycle. In this study, we present the commissioning process for an Anzai gating system (AZ-733VI) on an Elekta Versa HD linear accelerator and make recommendatio...

2014
EUN SEOK KIM SEUNG-GU YEO

Previous studies on advanced radiotherapy (RT) techniques for early stage glottic cancer have focused on sparing the carotid artery. However, the aim of the present study was to evaluate the dosimetric advantages of volumetric modulated arc therapy (VMAT) in terms of sparing the thyroid gland in early-stage glottic cancer patients. In total, 15 cT1N0M0 glottic cancer patients treated with defin...

2015
Wietse Eppinga Peter Vijverberg Rien Moerland Eric Brand Jochem van der Voort van Zyp Juus Noteboom Marco van Vulpen

We report a case of perineal recurrence of prostate cancer 6 years after low-dose-rate (LDR) brachytherapy for localized prostate cancer. The most common approach to treat such perineal masses, including those occurring after prior biopsy or surgery, is local excision. We report the use of stereotactic radiotherapy with volumetric modulated arc therapy (VMAT) as a novel non-invasive, potentiall...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید