Leon M. Tolbert Thomas G. Habetler

 Many definitions have been formulated to characterize non-active power for nonsinusoidal waveforms in electrical systems, and no single, universally valid power theory has been adopted as a standard for non-active power. Most of the non-active power theories formulated thus far have had a particular type of compensation in mind, which has influenced the conventions used in the development of ...

2015
Papan Dey

This study presents aD–Q current controlmethodwithmodified phase lock loop to generate the required reference current for shunt hybrid active filter (SHAPF) to improve the power quality. The performance of the proposed controller has been evaluated in terms of harmonic current mitigation and reactive power compensation under different grid conditions. Here, the passive elements of SHAPF have be...

In this paper we propose a suitable reference wave for Pulse Width Modulation (PWM) AC Drives. Staircase reference waves whose levels are calculated to eliminate certain harmonics are studied and a certain staircase reference waveform with L levels is constructed. When L is made very large in limit, this staircase waveform approaches a continuous one which is called Quasine (Quasi + Sine). This...

In this paper, a voltage-current mode controller is proposed to adjust both the input current and DC voltage of a boost-inverter in order to improve the performance of the photovoltaic (PV). The proposed system is based on fuzzy-making-decision predictive voltage-current controller (FPVCC). The simulation results show that in case of using the proposed FPVCC, the input current of a PV array is ...

A. A. Khodadoost Arani, A. Khoshsaadat, G. B. Gharehpetian, J. S. Moghani,

Multilevel voltage source inverters have several advantages compare to traditional voltage source inverter. These inverters reduce cost, get better voltage waveform and decrease Total Harmonic Distortion (THD) by increasing the levels of output voltage. In this paper Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) methods are used to find the switching angles for achieving to the m...

Abstract:Today, one of the important issues of power quality (PQ) in power systems is the current harmonics. Increasing expansion of nonlinear loads at different parts of the electric network makes harmonic distortion flow through the network. This causes the network to have background voltage and current harmonic distortion and even affect on the PQ of linear load performance. Therefore, it is...

2003
V. J. Gosbell V. W. Smith D. Robinson W. Miller

A modelling technique is developed for determining the harmonic voltage distribution across a distribution system when there is an equitable distribution of harmonic emission. The harmonic voltages at the 132kV and 415V levels are fixed to values based on IEC Compatibility and Planning Levels and the intermediate voltages determined. Studies are made of six systems, typical of Australian distri...

Hassan Taghizadeh Mehrdad Tarafdar Hagh

This paper presents a new method to find the optimum switching angles in voltage source multilevel converters in order to minimize specific higher order harmonics and decrease the total harmonic distortion (THD) of their output voltage waveform. The output voltage waveform of inverter can either be in the form of staircase or PWM. In order to increase the degrees of freedom and elimination of m...

2006
A. A. Latheef V. J. Gosbell V. Smith

The number of installations of photovoltaic solar panels and associated inverter systems within residential premises is increasing. As these systems incorporate a power electronics front end, they will have an influence on the quality of supply in regards to voltage harmonics. This paper investigates the harmonic impact on an 11kV distribution system due to the installation of residential type ...