نتایج جستجو برای: voltage and current harmonics compensation
تعداد نتایج: 16907144 فیلتر نتایج به سال:
The use of sensitive electronic equipment has increased now a days which has lead to power quality problems. The various power quality disturbances are transients, interruptions, voltage sag, voltage swell, voltage collapse, harmonics etc. To solve these power quality problems various custom power devices are used. Dynamic voltage restorer (DVR) is a custom power device used for the Compensatio...
This paper proposes the use of a Modular Marx Multilevel Converter, as a solution for energy integration between an offshore Wind Farm and the power grid network. The Marx modular multilevel converter is based on the Marx generator, and solves two typical problems in this type of multilevel topologies: modularity and dc capacitor voltage balancing. This paper details the strategy for dc capacit...
Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...
In this paper two types of current control techniques, namely, direct and indirect current control techniques are employed to a three phase shunt active power filter for the compensation of the harmonics in the current caused by the non-linear loads. The difference between these two types of current control technique is in the number of current sensors used. In direct current control technique ...
Application of PI controller based active filter for harmonic mitigation of grid-connected PV-system
The recent trends show the interconnection of PV system with electric grid. With this configuration issue harmonics comes into existence. mounting figure power-electronic instruments has formed considerable impression on power-quality supply. Harmonics deformations have conventionally been handled amid application passive-LC filters. Active Filter emerged as a good substitute for passive filter...
In this paper, a new control strategy is proposed for implementation in low-voltage microgrids with balanced/ unbalanced load circumstances. The proposed scheme contains, the power droop controllers, inner voltage and current loops, the virtual impedance loop, the voltage imbalance compensation. The proposed strategy balances the voltage of the single-phase critical loads by compensating the im...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید