نتایج جستجو برای: track detector
تعداد نتایج: 121041 فیلتر نتایج به سال:
Introduction: This study was conducted to measure the gamma emitters (e.g., uranium-238 [238U], thorium-232 [232Th], and potassium-40[40K]) and alpha emitters (e.g., radon-222 [222Rn] and radium), and also to evaluate the radiation hazard indices of radionuclides in parenteral nutrition samples utilized in the hospitals of Iraq. Material and Methods: The measurements were accomplished using ga...
In this paper, we propose a method to determine the equilibrium factor using a bare LR 115 detector. The partial sensitivities rhoi of the LR 115 detector to 222Rn and its alpha-emitting short-lived progeny, 218Po and 214Po, were investigated. We first determined the distributions of lengths of major and minor axes of the perforated alpha tracks in the LR 115 detector produced by 222Rn, 218Po a...
One of the keystones of the canceled BTeV experiment (proposed at Fermilab’s Tevatron) was its sophisticated threelevel trigger. The trigger was designed to reject 99.9% of lightquark background events and retain a large number of B decays. The BTeV Pixel Detector provided a 3-dimensional, high resolution tracking system to detect B signatures. The Level 1 pixel detector trigger was proposed as...
This report presents recent results on track reconstruction and alignment with the silicon tracker of the CMS experiment at the LHC, obtained with a full detector simulation. After an overview of the layout of the tracker and its material budget, the baseline algorithm for track reconstruction is discussed. The performance of the track reconstruction and its dependence on misalignment is shown....
Recently, Matiullah et al. described the use of NaOH/ethanol as an etchant for the CR-39 detector, and have determined the corresponding bulk and track etch properties from the track diameter method. In the present work, the bulk and track etch properties of CR39 in NaOH/ethanol were derived from direct measurements. The bulk etch rate has been found to increase with the molarity of NaOH/ ethan...
The solid state track detector of celluloid films (cellulose nitrate+camphor 25% an weight) using etching technique is suitable for low energy alpha particle detection . The critical rate of energy loss for track formation in celluloid films is determined as 1 .3 MeV/mg•Ecm2. Irradiated samples are etched in NaOH (6 N) solution at 46•Ž for 10 minutes . The etched tracks are observed under a vie...
current practices in railway track analysis and design are reviewed and discussed in this paper. the mechanical behavior of railway track structure comprising of various components has not been fully understood due to the railway track structural complexity. although there have been some improvements in the accuracy of current track design methods in recent decades, there are still considerable...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید