نتایج جستجو برای: ti implant

تعداد نتایج: 81242  

Journal: :Australian dental journal 2009
M A Alfarsi H Mehmet Okutan M Bickel

BACKGROUND This study evaluated the feasibility of fabricating implant abutments and crowns from pre-sintered feldspathic porcelain blocks using the chair-side CAD/CAM, CEREC3D((R)) system. METHODS Thirty-two implant analogues were divided into two groups. In the control group, prefabricated machined anatomical titanium (Ti) abutments were screw-retained to the analogues. In the test group, m...

2014
M. Khandaker U. KC A. Khadaka

Electrospinning is a process by which fibers with micron to nanometer diameters can be obtained from an electrostatically driven jet of polymer solution. These fibers have a high surface area to volume ratio, which have numerous applications in biomedical implants such as total hip implant, dental implant. The present study is based on the hypothesis that the differences of the surface properti...

2012
B. K. C. Ganesh N. Ramanaiah P. V. Chandrasekhar Rao

Titanium alloys are extensively used in various fields of engineering, medicine, aerospace, marine due to its excellent mechanical properties. Its usage is more pronounced today in the field of biomedical implants due to its superior biocompatibility, corrosive resistance and high strength to weight ratio. It has poor abrasive wear resistance due to high coefficient of friction and low thermal ...

Journal: :Journal of materials research and technology 2021

Abstract Substantial progress has been made in Ti alloys’ properties and chemical composition. However, the effect of porosity indium content on biocompatibility corrosion behavior not sufficiently studied. Indium (In) is a promising nontoxic element that can replace other toxic elements, while associated with good biological response. The purpose this paper to evaluate achievability three Ti–I...

Journal: :Biomedical materials 2014
Evans Chikarakara Patricia Fitzpatrick Eric Moore Tanya Levingstone Laura Grehan Clement Higginbotham Mercedes Vázquez Komal Bagga Sumsun Naher Dermot Brabazon

The success of any implant, dental or orthopaedic, is driven by the interaction of implant material with the surrounding tissue. In this context, the nature of the implant surface plays a direct role in determining the long term stability as physico-chemical properties of the surface affect cellular attachment, expression of proteins, and finally osseointegration. Thus to enhance the degree of ...

Journal: :Brazilian dental journal 2010
Samuel Porfírio Xavier Karen Emi Ikuno Marconi Gonzaga Tavares

It has recently been reported that machined and microrough (micro) Brazilian titanium (Ti) implants have good production standards. The aim of this study was to evaluate in vivo bone formation around 2 different implant surfaces placed in dog's mandible. Thirty-two screw-typed Ti implants were used in this study. Mandibular premolars were extracted in 8 dogs and, after 12 weeks, 2 machined (Neo...

2017
Xiaojing He Xiangyu Zhang Lin Qin

Ti and its alloys are the most commonly used materials for biomedical applications. However, bacterial infection after implant placement is still one of the significant rising complications. Therefore, the application of the antimicrobial agents into implant surfaces to prevent implant-associated infection has attracted lots of attentions. Scientific papers have shown that inorganic antibacteri...

2016
Esteban Pérez-Pevida Aritza Brizuela-Velasco David Chávarri-Prado Antonio Jiménez-Garrudo Fernando Sánchez-Lasheras Eneko Solaberrieta-Méndez Markel Diéguez-Pereira Felipe J Fernández-González Borja Dehesa-Ibarra Francesca Monticelli

The objective of the present study is to evaluate how the elastic properties of the fabrication material of dental implants influence peri-implant bone load transfer in terms of the magnitude and distribution of stress and deformation. A three-dimensional (3D) finite element analysis was performed; the model used was a section of mandibular bone with a single implant containing a cemented ceram...

Journal: :Brazilian dental journal 2008
Rosemeire de Lordo Franco Roberto Chiesa Paulo Tambasco de Oliveira Marcio Mateus Beloti Adalberto Luiz Rosa

This study evaluated bone response to a Ca- and P- enriched titanium (Ti) surface treated by a multiphase anodic spark deposition coating (BSP-AK). Two mongrel dogs received bilateral implantation of 3 Ti cylinders (4.1 x 12 mm) in the humerus, being either BSP-AK treated or untreated (machined - control). At 8 weeks postimplantation, bone fragments containing the implants were harvested and pr...

Journal: :International journal of odontostomatology 2023

This in silico study aimed to evaluate the biomechanical behavior of a full-arch implant-supported prosthesis on titanium and zirconia monotype implants. A 3D mandible containing 1.0 mm thick cortical cancellous bone was modeled. Four dental implants (3.3 x 10 mm) were inserted into jaw model each model. The consisted Titanium (Ti-S group) Zirconia Monotype/one-piece (Zr-S group). Fixed prosthe...