Alexandra Quinn Lois Holloway Dean Cutajar Nicholas Hardcastle Anatoly Rosenfeld Peter Metcalfe

PURPOSE Cone beam computed tomography (CBCT) is fast becoming standard on modern linear accelerators. CBCT increases the dose to regions within and outside the treatment field, potentially increasing secondary cancer induction and toxicity. This study quantified megavoltage (MV) CBCT skin dose and compared it to skin dose delivered during standard tangential breast radiotherapy. METHOD Dosime...

2011
Thomas Fearon Huchen Xie Jason Y. Cheng Holly Ning Ying Zhuge Robert W. Miller

Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of "standard man". Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of thi...

2017
Zaid Alnewaini Eric Langer Philipp Schaber Matthias David Dominik Kretz Volker Steil Jürgen Hesser

OBJECTIVES Dosimetric control of staff exposure during interventional procedures under fluoroscopy is of high relevance. In this paper, a novel ray casting approximation of radiation transport is presented and the potential and limitation vs. a full Monte Carlo transport and dose measurements are discussed. METHOD The x-ray source of a Siemens Axiom Artix C-arm is modeled by a virtual source ...

Journal: :European journal of radiology 2009
M Loubele R Bogaerts E Van Dijck R Pauwels S Vanheusden P Suetens G Marchal G Sanderink R Jacobs

OBJECTIVES To compare the effective dose levels of cone beam computed tomography (CBCT) for maxillofacial applications with those of multi-slice computed tomography (MSCT). STUDY DESIGN The effective doses of 3 CBCT scanners were estimated (Accuitomo 3D, i-CAT, and NewTom 3G) and compared to the dose levels for corresponding image acquisition protocols for 3 MSCT scanners (Somatom VolumeZoom ...

Journal: :Journal of radiological protection : official journal of the Society for Radiological Protection 2008
J A Cole D J Platten

Currently in the UK, shielding calculations for computed tomography (CT) systems are based on the BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) working group publication from 2000. Concerns have been raised internationally regarding the accuracy of the dose plots on which this method depends and the effect that new scanner technologies may have. A...

Journal: :Medical physics 2016
D Branco P Taylor S Frank H Li X Zhang H Mehrens M Guindani D Followill

PURPOSE To design a Head and Neck (H&N) anthropomorphic QA phantom that the Imaging and Radiation Oncology Core Houston (IROC-H) can use to verify the quality of intensity modulated proton therapy (IMPT) H&N treatments for institutions participating in NCI clinical trials. METHODS The phantom was created to serve as a remote auditing tool for IROC-H to evaluate an institution's IMPT planning ...

Journal: :Medical physics 2009
Bruce J Gerbi John A Antolak F Christopher Deibel David S Followill Michael G Herman Patrick D Higgins M Saiful Huq Dimitris N Mihailidis Ellen D Yorke Kenneth R Hogstrom Faiz M Khan

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of.Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance...

2014
Cassiane Cardoso Bonato Henrique Bregolin Dias Michele da Silva Alves Lucas Ost Duarte Telpo Martins Dias Maiara Oliveira Dalenogare Claudio Castelo Branco Viegas Regina Helena Elnecave

BACKGROUND Scattered radiation can be assessed by in vivo dosimetry. Thyroid tissue is sensitive to radiation, even at doses <10 cGy. This study compared the scattered dose to the thyroid measured by thermoluminescent dosimeters (TLDs) and the estimated one by treatment planning system (TPS). METHODS During radiotherapy to sites other than the thyroid of 16 children and adolescents, seventy-t...

Journal: :Investigative ophthalmology & visual science 1990
P T Finger T K Ho D M Fastenberg R A Hyman E M Stroh S Packer H D Perry

Iodine-based liquid radiographic contrast agents were placed in normal and tumor-bearing (Greene strain) rabbit eyes to evaluate their ability to block iodine-125 radiation. This experiment required the procedures of tumor implantation, vitrectomy, air-fluid exchange, and 125I plaque and thermoluminescent dosimetry (TLD) chip implantation. The authors quantified the amount of radiation attenuat...