نتایج جستجو برای: surface dose

تعداد نتایج: 932650  

ژورنال: سنجش و ایمنی پرتو 2019

Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...

Hamid Reza Baghani, Seyed Hamid Zoljalali Moghaddam Seyed Rabi Mahdavi

Introduction: The received dose to the surface of tumor bed is one of the main issues in beast intraopeative radiotherapy (IORT). Totally, the administered dose to the surface is usually lower than that of radiotherapy reference point (distal end of tumor bed). Employing a buildup bolus can effectively increase the surface dose and therefore, eliminate such created cold points ...

2014
Volker Rudat Alaa Nour Abdul Aziz Alaradi Adel Mohamed Saleh Altuwaijri

PURPOSE The purpose of this study was to compare the surface dose of 7-field IMRT (7 F-IMRT), tangential beam IMRT (TB-IMRT), and tangential beam 3D-CRT (3D-CRT) of breast cancer patients receiving adjuvant radiotherapy by means of in vivo GafChromic film dosimetry. MATERIAL AND METHODS Breast cancer patients receiving adjuvant radiotherapy of the whole breast or the chest wall were eligible ...

Journal: :Journal of the Korean Society of Radiology 2011

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2015

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

M Amir Bakhtiarvand M Rezaei Tavirani S Hesami Takallu SH Kalantari SM Mahdavi

Human serum albumin (HSA) is the most abundant plasma protein in the human body. HSA plays an important role in drug transport and metabolism. This protein has a high affinity to a very wide range of materials, including metals such as Cu2+ and Zn2+, fatty acids, amino acids and metabolites such as bilirubin and many drug compounds. In this study, we investigated the effects of co-amoxiclav, as...

H.P. Yadav, N.P. Patel, R. Shukla, V. Kaushal,

Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique.  Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...

Journal: :iranian journal of radiation research 0
m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. zabihzadeh department of medical physics, jondishapour university of medical sciences, ahvaz, iran m.r. ay department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran s.r. mahdavi department of medical physics, iran university of medical sciences, tehran, iran m. shahriari department of nuclear engineering, shahid beheshti university, tehran, iran a. mesbahi department of medical physics, tabriz university of medical sciences, tabriz, iran

background: the electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. the detailed characteristics of contaminant electrons are presented for different field sizes and cases. materials and methods: the monte carlo code, mcnpx, has been used to simulate 18 mv photon beam from a varian linac-2300 accelerator. all dose measurements were carried out u...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید