نتایج جستجو برای: stress shielding

تعداد نتایج: 447020  

2004
Lothar O. Hoeft

The relationship between surface transfer impedance and stirred mode chamber shielding effectiveness proposed by Eicher and Boillot has been simplified. This simplified relationship was used to compare the measured stirred mode chamber shielding effectiveness of nine shielding artifacts with the shielding effectiveness of the same samples calculated from transfer impedance measurements made at ...

Journal: :journal of biomedical physics and engineering 0
a r farajollahi f bouzarjomehri m kiani

normal 0 false false false en-us x-none fa introduction: in radiation therapy centers across iran, protection of normal tissues is usually accomplished by either cerrobend or lead block shielding. in this study, the influence of these two shielding methods on central axis dose distribution of photon beam a cobalt unit was investigated in clinical conditions. materials and methods: all measureme...

2014
Renate Wolf geb. Reisenauer Gesine Dreisbach Mark W. Greenlee Roland Thomaschke Johanna Bogon Svenja Böttcher

............................................................................................................. 8 I. Theoretical Background .................................................................... 9 Cognitive Control ............................................................................................................ 10 An Introduction to Cognitive Control.........................

Journal: :The Journal of bone and joint surgery. British volume 2011
B Melis M DeFranco A Lädermann D Molé L Favard C Nérot C Maynou G Walch

Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were ...

1998
C. Orzel S. D. Bergeson S. Kulin S. L. Rolston

Using 40 ns laser pulses, we probe the real-time dynamics of ultracold ionizing collisions in metastable xenon. We time resolve both shielding and enhancement effects, and observe the production of Xe2 molecular ions through associative ionization. We estimate the rate of molecule formation in excited-state collisions, and directly measure the role of both flux enhancement and excited state sur...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2010
A S Dickinson A C Taylor M Browne

Hip resurfacing is an established treatment for osteoarthritis in young active patients. Failure modes include femoral neck fracture and prosthesis loosening, which may be associated with medium-term bone adaptation, including femoral neck narrowing and densification around the prosthesis stem. Finite element modelling was used to indicate the effects of prosthesis sizing and positioning on the...

2017
Fei Yang Chen Chen QianRong Zhou YiMing Gong RuiXue Li ChiChi Li Florian Klämpfl Sebastian Freund XingWen Wu Yang Sun Xiang Li Michael Schmidt Duan Ma YouCheng Yu

Fabricating Ti alloy based dental implants with defined porous scaffold structure is a promising strategy for improving the osteoinduction of implants. In this study, we use Laser Beam Melting (LBM) 3D printing technique to fabricate porous Ti6Al4V dental implant prototypes with three controlled pore sizes (200, 350 and 500 μm). The mechanical stress distribution in the surrounding bone tissue ...

Journal: :Clinical orthopaedics and related research 2010
Nobuo Nakamura Nobuhiko Sugano Takashi Nishii Akihiro Kakimoto Hidenobu Miki

BACKGROUND The benefits of robotic techniques for implanting femoral components during THA are still controversial. QUESTIONS/PURPOSES The purpose of this study was to prospectively compare the results and complications of robotic-assisted and hand-rasping stem implantation techniques. METHOD The minimum followup was 5 years (mean, 67 months; range, 60-85 months). One hundred forty-six prim...

2007
G. Fehrenbacher E. Kozlova

Shielding calculations are done for the following scenario: a graphite target is hit by a 1 GeV/u U beam with an intensity of 10 particles per second. The target is a wheel with radius of 22.5 cm and it is subdivided into three rings, each 16 mm wide, with thicknesses of 21.6, 32.4 and 43.2 mm, corresponding to 4, 6, 8 g/cm [3]. For a conservative case the thickest part of the target with a thi...

2017
Yucheng Gao Wei Zhao Qing Wang Kaifeng Qu He Li Haiming Shao Songling Huang

Applying shielding coils is a practical way to protect current transformers (CTs) for large-capacity generators from the intensive magnetic interference produced by adjacent bus-bars. The aim of this study is to build a simple analytical model for the shielding coils, from which the optimization of the shielding coils can be calculated effectively. Based on an existing stray flux model, a new a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید