نتایج جستجو برای: stress rest mpi

تعداد نتایج: 518342  

Journal: :Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2002
Habib Samady Frans J Th Wackers Tammy M Joska Barry L Zaret Diwakar Jain

BACKGROUND Adenosine is commonly used for pharmacologic stress myocardial perfusion imaging (MPI). However, it frequently results in adverse effects, and the subdiaphragmatic tracer uptake may interfere with the image interpretation. Our aim was to determine the feasibility of combining low-level treadmill exercise with adenosine MPI and its impact on adverse effects, image quality, and myocard...

Journal: :The Journal of the Association of Physicians of India 2003
R D Lele

In this issue of JAPI there are two articles on the evaluation of suspected or known coronary artery disease : comparison of stress ECG and stress myocardial perfusion imaging (MPI), and adenosine stress MPI. This is a good opportunity to review the subject of evaluation of Coronary Artery Disease (CAD). The views expressed are based on my personal experience of 25 years in nuclear cardiology a...

Journal: :Circulation 2008
Aaron L Baggish Charles A Boucher

Myocardial perfusion imaging (MPI) is a wellestablished noninvasive method of assessing coronary blood flow.1–5 MPI is capable of identifying regional abnormalities in coronary artery blood flow and determining their physiological relevance to myocardial function and viability. MPI requires the intravenous injection of a radioactive blood flow marker followed by imaging of regional myocardial u...

2016
C I Aquino M Scarano F Squame G Casaburi S L Nori L Pace

BACKGROUND Myocardial perfusion imaging (MPI) with single photon emission tomography (SPET) is widely used in coronary artery disease evaluation. Recently major dosimetric concerns have arisen. The aim of this study was to evaluate if a pre-test scoring system could predict the results of stress SPET MPI, thus avoiding two radionuclide injections. METHODS All consecutive patients (n=309) unde...

2005
IAN K. BAILEY H. WILLIAM STRAUSS BERTRAM PITT

The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise ...

Journal: :CoRR 2003
Masao Okita Fumihiko Ino Kenichi Hagihara

In message passing programs, once a process terminates with an unexpected error, the terminated process can propagate the error to the rest of processes through communication dependencies, resulting in a program failure. Therefore, to locate faults, developers must identify the group of processes involved in the original error and faulty processes that activate faults. This paper presents a nov...

Journal: :Circulation. Cardiovascular imaging 2009
Robert B McCully Patricia A Pellikka David O Hodge Philip A Araoz Todd D Miller Raymond J Gibbons

BACKGROUND Appropriateness criteria for stress imaging have been published to promote the effective use of stress nuclear scintigraphy and stress echocardiography. We sought to evaluate the application of the stress echocardiography appropriateness criteria to patients undergoing stress echocardiography in an academic medical center. METHODS AND RESULTS The stress echocardiography criteria we...

Journal: :Journal of the American College of Cardiology 2005
Benjamin J W Chow Karthikeyan Ananthasubramaniam Robert A dekemp Mary M Dalipaj Rob S B Beanlands Terrence D Ruddy

OBJECTIVES This study assessed the feasibility of treadmill exercise rubidium-82 ((82)Rb) positron emission tomography (PET) and compared image quality and diagnostic content with dipyridamole (82)Rb PET in patients referred for evaluation of coronary artery disease (CAD). BACKGROUND Dipyridamole stress (82)Rb PET myocardial perfusion imaging (MPI) is an accurate imaging modality used to diag...

Journal: :Journal of the American College of Cardiology 2008
Raymond J Gibbons Todd D Miller David Hodge Lynn Urban Philip A Araoz Patricia Pellikka Robert B McCully

OBJECTIVES The purpose of this study was to apply published appropriateness criteria for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in a single academic medical center. BACKGROUND The American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC) have developed appropriateness criteria for stress SPECT MPI to a...

Journal: :Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2017
Georgios Christopoulos John Bois Thomas G Allison Martin Rodriguez-Porcel Panithaya Chareonthaitawee

OBJECTIVE The diagnostic yield of combined cardiopulmonary exercise testing (CPET) and myocardial perfusion imaging (MPI) in patients referred for stress testing has received limited study. METHODS We evaluated consecutive patients who underwent combined CPET-MPI at a single tertiary referral center between 2011 and 2015. An abnormal CPET was defined as any of the following: reduced oxygen co...

نمودار تعداد نتایج جستجو در هر سال