نتایج جستجو برای: steel coils
تعداد نتایج: 89035 فیلتر نتایج به سال:
PURPOSE To evaluate the physical characteristics and behavior of coils for endovascular therapy. METHODS Mechanically detachable coils were constructed with simple helical (4 mm X 10 cm and 8 mm X 30 cm) and pretzel shapes (4 mm X 5 cm) made from three metals using 0.003- and 0.004-in wire. Stiffness or pliability, frictional resistance, shape memory, and coil stability were evaluated in vitr...
Nine embolization experiments of a silicone aneurysm model were conducted by using helical and complex-shaped coils. Coils were introduced up to the point when the adjunct of a supplementary coil caused protrusion into the parent vessel. Packing ratios (volume of coils-aneurysm volume) ranged between 31% and 38%. Optimal packing was achieved with complex-shaped coils used in a concentric fashio...
Our clinical experience with interlocking detachable coils for the embolization of high-flow dural arteriovenous fistulas is reported. Interlocking detachable coils are useful for transarterial and transvenous embolizations of dural arteriovenous fistulas because (a) immediate coil detachment is possible, (b) the coils can be replaced easily, (c) detached coils rarely migrate, and (d) fewer int...
the star-mesh transformation allows the reduction of nodes in an electrical circuit. the gauss elimination method allows the reduction of unknowns in a system of linear equations . triangular decomposition can be used to find the inverse of a matrix. in this paper the coherence between these methods are discussed. it is shown that the gauss elimination method gives the same formula for star-mes...
introduction the aim of this study was to compare the characteristics of deflection load of three kinds of nickel titanium closed coil springs. methods and materials this research was an experimental study. research sample contains three kinds of niti closed coiled springs (heavy, medium, light) from gac, 3m, and rmo factories. 10 springs with 9 mm length for each group (totally 90 springs) wer...
BACKGROUND AND PURPOSE The purpose of this study was to retrospectively compare the packing performance of helical Guglielmi detachable coil (GDC) 18 (thickness, 0.0135-0.015 inch) with the packing performance of both helical GDC 10 (thickness, 0.010 inch) and complex Trufill/Orbit coils (thickness, 0.012 inch). MATERIALS AND METHODS From our data base, we selected aneurysms that were exclusi...
MgB2 wire and tape were prepared using the powder in tube and reaction in-situ technique. All samples were characterized using the XRD, SEM, TEM, as well as transport and magnetic measurements. High transport and magnetic critical current density values have been obtained for metal-clad wires and tapes. Different sheath materials have been examined, but Fe appears to be the best sheath for MgB...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید