نتایج جستجو برای: solid phantom

تعداد نتایج: 206123  

Journal: :trauma monthly 0
mohammad h ebrahimzadeh department of orthopedic surgery, ghaem hospital, mashhad university of medical science, mashhad, ir iran amir r kachooei department of orthopedic surgery, ghaem hospital, mashhad university of medical science, mashhad, ir iran ali moradi department of orthopedic surgery, ghaem hospital, mashhad university of medical science, mashhad, ir iran h azema janbazan medical and engineering research center, tehran, ir iran

background long-term clinical symptoms and functional status of above-knee amputees are not well documented. this study documents the long-term outcomes of war related above-knee amputations. objective to study the long-term outcomes of unilateral above-knee amputation. materials and methods the study consisted of a comprehensive assessment, examination, and review of history and wartime medica...

2008
Gareth J. Webster Mark J. Hardy Carl G. Rowbottom Ranald I. Mackay

The head and neck is a challenging anatomic site for intensity-modulated radiation therapy (IMRT), requiring thorough testing of planning and treatment delivery systems. Ideally, the phantoms used should be anatomically realistic, have radiologic properties identical to those of the tissues concerned, and allow for the use of a variety of devices to verify dose and dose distribution in any targ...

2013
Yasuyuki Takahashi Masao Miyagawa Yoshiko Nishiyama Hayato Ishimura Teruhito Mochizuki

OBJECTIVE The performance of a new single photon emission computed tomography (SPECT) scanner with a cadmium-zinc-telluride (CZT) solid-state semiconductor detector (Discovery NM 530c; D530c) was evaluated and compared to a conventional Anger-type SPECT with a dual-detector camera (Infinia). METHODS Three different phantom studies were performed. Full width at half maximum (FWHM) was measured...

2013
Larissa Thompson Humberto Galvão Dias Tarcísio Passos Ribeiro Campos

Glioblastoma multiforme (GBM) is the most common, aggressive, highly malignant and infiltrative of all brain tumors with low rate of control. The main goal of this work was to evaluate the spatial dose distribution into a GBM simulator inside a head phantom exposed to a 15 MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Ra...

2016
Moti R. Paudel Anthony Kim Arman Sarfehnia Sayed B. Ahmad David J. Beachey Arjun Sahgal Brian M. Keller

A new GPU-based Monte Carlo dose calculation algorithm (GPUMCD), devel-oped by the vendor Elekta for the Monaco treatment planning system (TPS), is capable of modeling dose for both a standard linear accelerator and an Elekta MRI linear accelerator. We have experimentally evaluated this algorithm for a standard Elekta Agility linear accelerator. A beam model was developed in the Monaco TPS (res...

Journal: :Journal of biomedical optics 2017
Gordon T Kennedy Griffin R Lentsch Brandon Trieu Adrien Ponticorvo Rolf B Saager Anthony J Durkin

Tissue simulating phantoms can provide a valuable platform for quantitative evaluation of the performance of diffuse optical devices. While solid phantoms have been developed for applications related to characterizing exogenous fluorescence and intrinsic chromophores such as hemoglobin and melanin, we report the development of a poly(dimethylsiloxane) (PDMS) tissue phantom that mimics the spect...

Journal: :iranian journal of radiation research 0
a. mesbahi medical physics department, medical school and radiation oncology department, imam khomeini hospital, tabriz university of medical sciences, tabriz, iran

background: prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. to study the lung absorbed dose in radiotherapy with small fields,...

Journal: :Concepts in magnetic resonance. Part B, Magnetic resonance engineering 2006
Wanzhan Liu Shutong Zhang Christopher M Collins Jianli Wang Michael B Smith

Four 12-rung linear birdcage-type coils were built to experimentally examine the effects of the end-ring/shield configuration on radiofrequency magnetic field (B(1)) homogeneity and SNR at 125 MHz. The coil configurations include (a) a cylindrical shield (conventional), (b) a shield with annular extensions to closely shield the end-rings (surrounding shield), (c) a shield with annular extension...

Journal: :Physics in medicine and biology 2001
M J Butson T Cheung P K Yu

Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of film orientation during irradiation in water are also tested. Results show that only a small penetration rate ...

2013
Robert J. Cropp Petar Seslija David Tso Yogesh Thakur

Quality control testing of CT scanners in our region includes a measurement of CT numbers in the American College of Radiology (ACR) CT phantom using a standardized protocol. CT number values are clinically relevant in determining the composition of various tissues in the body. Accuracy is important in the characterization of tumors, assessment of coronary calcium, and identification of urinary...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید