نتایج جستجو برای: rando phantom

تعداد نتایج: 17378  

2015
Juha Koivisto Timo Kiljunen Nils Kadesjö Xie-Qi Shi Jan Wolff

BACKGROUND The aim of this study was to assess and compare the effective doses (ICRP 103) in the ankle region of X-ray imaging resulting from a multi slice computed tomography (MSCT) device, two cone beam CT (CBCT) devices and one conventional x-ray device. METHODS Organ dose measurements were performed using 20 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a cus...

Journal: :AJNR. American journal of neuroradiology 2006
M Cohnen H-J Wittsack S Assadi K Muskalla A Ringelstein L W Poll A Saleh U Mödder

BACKGROUND AND PURPOSE To assess patient radiation exposure in comprehensive stroke imaging using multidetector row CT (MDCT) combining standard CT of the head, cerebral perfusion (CTP), and CT angiography (CTA) studies. METHODS Examination protocols for CT and CTA of cerebral and cervical vessels, as well as CTP were simulated using a Somatom Sensation Cardiac 64. Effective doses were derive...

Journal: :The British journal of radiology 2009
J A Roberts N A Drage J Davies D W Thomas

Cone beam CT (CBCT) is becoming an increasingly utilized imaging modality for dental examinations in the UK. Previous studies have presented little information on patient dose for the range of fields of view (FOVs) that can be utilized. The purpose of the study was therefore to calculate the effective dose delivered to the patient during a selection of CBCT examinations performed in dentistry. ...

2017
Bagher Farhood Mohammad Taghi Bahreyni Toossi Shokouhozaman Soleymanifard Tohid Mortezazadeh

Aim of the study Our objective was to quantify the accuracy of dose calculation in the build-up region of the tangential field of the breast for a TiGRT treatment planning system (TPS). Material and methods Thermoluminescent dosimeter (TLD) chips were arranged in a RANDO phantom for the dose measurement. TiGRT TPS was also used for the dose calculation. Finally, confidence limit values were o...

Hamidreza Baghani, Hossein Gharaati, Seyed Mahmoodreza Aghamiri Seyed Rabie Mahdavi

Introduction: Orthogonal radial fields are those in which the central axes are perpendicular to each other. An example of these orthogonal fields is the set of craniospinal orthogonal fields that are used for radiotherapy of medulloblastoma. Craniospinal radial fields consist of two parallel-opposed fields for brain exposure and one or two posterior spinal fields for spinal cord exposure. The m...

2016
Narottam Lamichhane Vivek N. Patel Matthew T. Studenski

Accurate dose calculation and treatment delivery is essential for total body irradiation (TBI). In an effort to verify the accuracy of TBI dose calculation at our institution, we evaluated both the Varian Eclipse AAA and Acuros algorithms to predict dose distributions at an extended source-to-surface distance (SSD) of 400 cm. Measurements were compared to calculated values for a 6 MV beam in ph...

Journal: :Dento maxillo facial radiology 2004
D Schulze M Heiland H Thurmann G Adam

OBJECTIVES Radiation doses were determined to balance risks against usefulness of the different modalities available for the imaging of the facial skeleton. METHODS An Alderson Rando Phantom, armed with lithium fluoride thermoluminescent dosemeters (TLDs) was exposed using a set of four conventional radiographs (orbital view, modified Waters view, orthopantomography, skull posterior--anterior...

Journal: :Anticancer research 2013
Hideya Yamazaki Kazuki Iwama Takuya Nishimura Yasunori Iwai Norihiro Aibe Tadashi Takenaka Shunsuke Miyake Eiichi Tanaka Ken Yoshida Yoshitaka Oota Hiroyasu Ikeno Satoakai Nakamura Haruumi Okabe

AIM To examine the compatibility of the measured and calculated dose for the treatment of lung lesions by helical tomotherapy. MATERIALS AND METHODS The administered dose was measured a total of 55 times at 22 points with a radiophotoluminescence glass dosimeter (RPLGD) inserted in the position of an anthropomorphic Rando Phantom. Two Gy were prescribed and calculated with a tomotherapy plann...

2014
Ahmad Nobah Saad Aldelaijan Slobodan Devic Nada Tomic Jan Seuntjens Mohammad Al‐Shabanah Belal Moftah

In this work we compare doses from imaging procedures performed on today's state-of-the-art integrated imaging systems using a reference radiochromic film dosimetry system. Skin dose and dose profile measurements from different imaging systems were performed using radiochromic films at different anatomical sites on a humanoid RANDO phantom. EBT3 film was used to measure imaging doses from a Tom...

2012
Dominik Ketelsen Markus Buchgeister Andreas Korn Michael Fenchel Bernhard Schmidt Thomas G. Flohr Christoph Thomas Christoph Schabel Ilias Tsiflikas Roland Syha Claus D. Claussen Martin Heuschmid

Purpose. To estimate effective dose and organ equivalent doses of prospective ECG-triggered high-pitch CTCA. Materials and Methods. For dose measurements, an Alderson-Rando phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a second-generation dual-source scanner (SOMATOM Definition Flash, Siemens Medic...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید