نتایج جستجو برای: pvc based membrane

تعداد نتایج: 3283838  

2007
Joaquín A. Ortuño Vicente Ródenas Mª Soledad García Mª Isabel Albero Concepción Sánchez-Pedreño

The construction and electrochemical response characteristics of a poly(vinyl chloride) (PVC) membrane selective electrode for the determination of tiapride (TPD) are described. The sensing membrane comprised an ion-pair formed between the protonated drug and tetraphenylborate (TPB) in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The ele...

2009
Junqi Wang Yi Cai Yansong Miao Sheung Kwan Lam Liwen Jiang

Wortmannin, a specific inhibitor of phosphatidyl-inositol 3-kinase, is a useful tool for studying protein trafficking and identifying organelles in the plant secretory and endocytic pathways. It has recently been demonstrated that wortmannin at 16.5 microM or 33 microM caused the prevacuolar compartments (PVCs), identified as multivesicular bodies (MVBs) by their enrichment in vacuolar sorting ...

Journal: :Materials Today: Proceedings 2021

Journal: :IOSR Journal of Applied Chemistry 2012

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2010
Toshiaki Hattori Yoshitomo Masaki Kazuya Atsumi Ryo Kato Kazuaki Sawada

Two-dimensional real-time observation of potassium ion distributions was achieved using an ion imaging device based on charge-coupled device (CCD) and metal-oxide semiconductor technologies, and an ion selective membrane. The CCD potassium ion image sensor was equipped with an array of 32 × 32 pixels (1024 pixels). It could record five frames per second with an area of 4.16 × 4.16 mm(2). Potass...

2007
Joaquin A. Ortuño Carlos Rueda

A flow-injection pulse amperometric method for determining tacrine, based on ion transfer across a plasticized poly(vinyl chloride) (PVC) membrane, was developed. A four-electrode potentiostat with ohmic drop compensation was used, while a flow-through cell incorporated the four electrodes and the membrane, which contained tetrabutylammonium tetraphenylborate. The influence of the applied poten...

K. Zare M. Aghaie M. Giahi

In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید