نتایج جستجو برای: pulse ratio

تعداد نتایج: 585102  

2017
A. T. Clausen H. N. Poulsen

A simulation model for investigating the impact of incoherent crosstalk due to pulse tail overlapping is proposed. Requirements to pulse width and Pulse Tail Extinction Ratio introducing a maximum of 1 dB penalty is extracted. Introduction Optical Time Division Multiplexing (OTDM) is an attractive technique to increase the overall capacity of optical communication systems, either as ultra-high ...

Journal: :Chest 2005
Marvin A Sackner Emerance Gummels Jose A Adams

STUDY OBJECTIVE To determine if comfortably applied, whole-body, periodic acceleration releases significant amounts of nitric oxide (NO) into the circulation of healthy subjects and patients with inflammatory diseases. MATERIALS Fourteen healthy adults and 40 adult patients with inflammatory diseases underwent single 45-min trials of whole-body, periodic acceleration with a new "passive exerc...

Journal: :international journal of advanced structural engineering 2009
li shuang zhai changhai xie lili

near-fault ground motions with long-period pulses can place severe demands on structures near an active fault. these pulse-type ground motions can be represented by pulse sequences with simple shapes. half-sinusoidal pulse sequences are used to approximate recorded ground motions and dynamic responses of sdof system under the excitation of these pulse sequences are studied. four cases are consi...

Journal: :Hypertension 2014
Yu-Mei Gu Lutgarde Thijs Yan Li Kei Asayama José Boggia Tine W Hansen Yan-Ping Liu Takayoshi Ohkubo Kristina Björklund-Bodegård Jørgen Jeppesen Eamon Dolan Christian Torp-Pedersen Tatiana Kuznetsova Katarzyna Stolarz-Skrzypek Valérie Tikhonoff Sofia Malyutina Edoardo Casiglia Yuri Nikitin Lars Lind Edgardo Sandoya Kalina Kawecka-Jaszcz Yutaka Imai Luis J Mena Jiguang Wang Eoin O'Brien Peter Verhamme Jan Filipovsky Gladys E Maestre Jan A Staessen

Evidence-based thresholds for risk stratification based on pulse pressure (PP) are currently unavailable. To derive outcome-driven thresholds for the 24-hour ambulatory PP, we analyzed 9938 participants randomly recruited from 11 populations (47.3% women). After age stratification (<60 versus ≥60 years) and using average risk as reference, we computed multivariable-adjusted hazard ratios (HRs) ...

2009
Yingrui Hu

Traditional stepped frequency chirp pulse train methods suffer from high sidelobes and ambiguous peaks, known as grating lobes and difficulty in compensating Doppler effect caused by target motion. This paper investigates a class of non-linear stepped frequency chirp pulse train with low sidelobes and capability to cancel clutter and to compensate motion. We present analytic expression for its ...

2017
Yurie Obata Qi J. Ong J. T. Magruder Helen Grichkevitch Dan E. Berkowitz Daniel Nyhan Jochen Steppan Viachaslau Barodka

Background: The effects of position and exercise on pulse wave distribution across a healthy, compliant arterial tree are not fully understood. We studied the effects of exercise and position on the pattern of pulse arrival times (PATs) in healthy volunteers. Moreover, we compared the pulse arrival time ratios to the respective distance ratios between different locations. Methods: Thirteen youn...

2014

One fundamental issue in designing a good radar system is it’s capability to resolve two small targets that are located at long range with very small separation between them. Pulse compression techniques are used in radar systems to avail the benefits of large range detection capability of long duration pulse and high range resolution capability of short duration pulse. In these techniques a lo...

Journal: :Lancet 2014
Qu-ming Zhao Xiao-jing Ma Xiao-ling Ge Fang Liu Wei-li Yan Lin Wu Ming Ye Xue-cun Liang Jing Zhang Yan Gao Bing Jia Guo-ying Huang

BACKGROUND Several pioneering studies have provided evidence for the introduction of universal pulse oximetry screening for critical congenital heart disease. However, whether the benefits of screening reported in studies from high-income countries would translate with similar success to low-income countries is unknown. We assessed the feasibility and reliability of pulse oximetry plus clinical...

2000
J. L. Schiano M. D. Ginsberg

A pulsed NQR spectrometer specifically designed to facilitate real-time tuning of pulse sequence parameters is described. A modular approach based on the interconnection of several rack-mounted blocks provides easy access to all spectrometer signals and simplifies the task of modifying the spectrometer design. We also present experimental data that demonstrates the ability of the spectrometer t...

Journal: :Optics letters 1998
R M Mu V S Grigoryan C R Menyuk E A Golovchenko A N Pilipetskii

We found by using Monte Carlo simulations that the timing jitter in a dispersion-managed soliton system decreases as the strength of the dispersion management and hence the ratio of the pulse energy to the pulse bandwidth increases. The results are in qualitative but not quantitative agreement with earlier predictions that the decrease is inversely proportional to the square root of the pulse e...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید