نتایج جستجو برای: plate fixation

تعداد نتایج: 121886  

Journal: :Orthopaedics & traumatology, surgery & research : OTSR 2011
M Ehlinger D Brinkert J Besse P Adam Y Arlettaz F Bonnomet

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

Journal: :Orthopedics 2011
Karl Wu Chih-Hung Chang Rong-Sen Yang

The purpose of this study was to compare outcomes and complications of clavicular hook plate and Kirschner tension band wiring for fixation of unstable lateral clavicle fractures. The surgical outcomes of 92 consecutive patients (mean age, 49.30 ± 15.54 years) with unstable fractures of the lateral clavicle treated using AO clavicle hook plates were compared with those of 24 patients (mean age,...

Journal: :Injury 2003
Emanuel Gautier Christoph Sommer

The Locking Compression Plate (LCP), in combination with the LISS and the PHILOS, is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. The following guidelines are needed to avoid failures and possible complications in the hands of surgeons not yet confident with the new implant philosophy. The...

2015
Yanping Fan Jianyin Lei Feng Zhu Zhiqiang Li Weiyi Chen Ximing Liu

This study aims to evaluate the biomechanical mechanism of fixation systems in the most frequent T-shaped acetabular fracture using finite element method. The treatment of acetabular fractures was based on extensive clinical experience. Three commonly accepted rigid fixation methods (double column reconstruction plates (P × 2), anterior column plate combined with posterior column screws (P + PS...

Journal: :Journal of pediatric orthopedics 2016
Ying Li Peter Helvie Frances A Farley Matthew D Abbott Michelle S Caird

BACKGROUND Operative treatment of displaced pediatric midshaft clavicle fractures has become increasingly popular, despite lack of evidence that surgical management leads to superior outcomes. Complications, such as plate irritation necessitating removal and wound infection, have been reported in adults. The purpose of this study was to evaluate complications after plate fixation of midshaft cl...

Journal: :Acta orthopaedica et traumatologica turcica 2013
Orcun Sahin Hüseyin Demirörs Rahmi Can Akgün Ismail Cengiz Tuncay

OBJECTIVE The purpose of this study was to analyze and compare the mechanical characteristics of a new iliosacral fixation technique (bilateral S1 pedicle fixation through a transiliac locked plate) for bilateral sacroiliac dislocations with other previously described methods. METHODS Bilateral sacroiliac dislocations were created in 21 pelvic models and divided into three different fixation ...

2014
Chu-Song Zhou Yan-Fang Xu Yu Zhang Zhong Chen Hai Lv

BACKGROUND Expandable screws have greater pullout strength than conventional screws. The purpose of this study was to compare the biomechanical stability provided by a new built-in expandable anterior spinal fixation system with that of 2 commonly used anterior fixation systems, the Z-Plate and the Kaneda, in a porcine partial vertebral corpectomy model. METHODS Eighteen porcine thoracolumbar...

Journal: :Journal of orthopaedic trauma 2008
Eric J Strauss Ran Schwarzkopf Frederick Kummer Kenneth A Egol

Locked plate technology has evolved in an effort to overcome the limitations associated with conventional plating methods, primarily for improving fixation in osteopenic bone. The development of screw torque and plate-bone interface friction is unnecessary with locked plate designs, significantly decreasing the amount of soft tissue dissection required for implantation, preserving the periostea...

Journal: :The archives of bone and joint surgery 2017
Leif Claassen Christian Plaass Marc-Frederic Pastor Sarah Ettinger Mathias Wellmann Christina Stukenborg-Colsman Hazibullah Waizy Sayyed Hadi Sayyed Hosseinian

BACKGROUND Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. There are still few comparable clinical data regarding this procedure. In this study we aimed to compare the clinical and radiographical outcomes of crossed-screws, locking and non-locking plate fixation with lag screw for first metatarsophalangeal joint arthrodesis. METHODS A total...

Journal: :The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons 2001
D J Buranosky D T Taylor R A Sage M Sartori A Patwardhan M Phelan A T Lam

Quantitative strength analysis of first metatarsophalangeal joint arthrodesis was performed using two fixation techniques: a small 6-hole plate with an interfragmentary screw or two crossed lag screws. Twelve matched-pair fresh-frozen cadaveric specimens (24 trials) were used for direct comparison of each of the two fixation techniques. All joint surfaces were prepared with power conical reamer...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید