نتایج جستجو برای: photon beam

تعداد نتایج: 178633  

2008
R. Appleby

The intense beam-beam effect at the interaction point of the International Linear Collider (ILC) causes large disruption of the beams and the production of photons. These photons, arising dominantly through beamstrahlung emission, are problematic for the machine design as they need to be transported and dumped in a controlled way. In this work, we perform simulations of the beam-beam interactio...

2004
E. L. Saldin M. V. Yurkov

X-ray photon beam from a SASE FEL undulator is in principle a single user tool, just like an optical laser. Therefore, the operation and amortization cost cannot be easily spread over many simultaneous experiments. To avoid prohibitive cost for each experiment, a new XFEL laboratory scheme is proposed. The wavelength range 0.1-1.6 nm at fixed electron energy of 15 GeV can be covered by operatin...

2016
Hartmut Haeffner Kelsey Johnsen

1 Quantum Interference and Entanglement Lab 2 Acknowledgements 3 Apparatus 3.1 Blue Laser Beam Path 3.2 Downconverted Photon Beam Path 3.3 Single Photon Detectors and Coincidence Detection 4 Equipment Notes 4.1 Single Photon Detectors 5 Using the LabVIEW Program 6 Viewing/Loading a Program on the DE2-115 7 Procedure for Bell's Inequality 7.1 A Quicker Estimate of S 8 Optimizing the Bell state 9...

2008
V. Kleber Friedrich Klein Frank Klein

In photoproduction experiments, a large number of final states yielding various resonance contributions are accessible. To extract resonance parameters via partial-wave analysis not only the measurement of differential cross-sections is necessary, but also the determination of polarization observables. At the electron accelerator ELSA (Bonn) the coherent bremsstrahlung method was used to genera...

Journal: :Physical review letters 2003
T B Pittman J D Franson

We report a violation of Bell's inequality using one photon from a parametric down-conversion source and a second photon from an attenuated laser beam. The two photons were entangled at a beam splitter using the postselection technique of Shih and Alley [Phys. Rev. Lett. 61, 2921 (1988)]]. A quantum interference pattern with a visibility of 91% was obtained using the photons from these independ...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

Journal: :Science 1963
J R CAMERON J SORENSON

The mineral content of bone can be determined by measuring the absorption by bone of a monochromatic, low-energy photon beam which originates in a radioactive source (iodine-125 at 27.3 kev or americium 241 at 59.6 kev). The intensity of the beam transmitted by the bone is measured by counting with a scintillation detector. Since the photon source and detector are well collimated, errors result...

2001
XuBo Zou K. Pahlke

We firstly present a feasible scheme to produce entangled spin-1 photon states from Fock state. The scheme requires only linear optical element and photon detector. The probability of success of method is relatively low. We further give a scheme to show that, if two maximally entangled photon state is prepared in advance, the probability of success can be improved. PACS number:03.65.Ud,42.50.Dv...

Journal: :Optics express 2006
N González G Molina-Terriza J P Torres

It is generally assumed that a light beam with orbital angular momentum (OAM) per photon of lh, is transformed, when traversing a Dove prism, into a light beam with OAM per photon of -lh. In this paper, we show theoretically and experimentally that this OAM transformation rule does not apply for highly focused light beams. This result should be taken into account when designing classical and qu...

2013
Yunfei Huang Ryan T. Flynn R. Alfredo C. Siochi John E. Bayouth

The clinical application of the flattening filter-free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high-dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of mode...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید