نتایج جستجو برای: phosphorescence

تعداد نتایج: 1605  

Journal: :Journal of Materials Chemistry C 2023

Circularly polarized organic room temperature phosphorescence (CPRTP) with g max = +0.098 was activated by the rigid environment of an in situ cross-linked liquid crystalline polymer network.

Journal: :Chemical communications 2012
Mouchumi Bhuyan Burkhard Koenig

Self-assembled lipid vesicles with embedded amphiphilic terbium(III) complexes show a strong temperature dependence of their phosphorescence intensity and lifetime in the physiological range.

Journal: :ACS Applied Materials & Interfaces 2021

Room temperature phosphorescence materials offer great opportunities for applications in optoelectronics, due to their unique photophysical characteristics. However, heavy-atom-free organic emitters that can realize distinct electrophosphorescence are rarely exploited. Herein a new approach designing room light-emitting diodes is presented. The subtle tuning of the singlet and triplet excited s...

2008
Joop J. Gilijamse Steven Hoekstra Samuel A. Meek Gerard Meijer Gerrit C. Groenenboom

We present a combined experimental and theoretical study on the radiative lifetime of CO in the aΠ1,2, v = 0 state. CO molecules in a beam are prepared in selected rotational levels of this metastable state, Stark-decelerated and electrostatically trapped. From the phosphorescence decay in the trap, the radiative lifetime is measured to be 2.63 ± 0.03 ms for the aΠ1, v = 0, J = 1 level. From sp...

2007
Joop J. Gilijamse Steven Hoekstra Samuel A. Meek Markus Metsälä Gerard Meijer Gerrit C. Groenenboom

We present a combined experimental and theoretical study on the radiative lifetime of CO in the aΠ1,2, v = 0 state. CO molecules in a beam are prepared in selected rotational levels of this metastable state, Stark-decelerated and electrostatically trapped. From the phosphorescence decay in the trap, the radiative lifetime is measured to be 2.63 ± 0.03 ms for the aΠ1, v = 0, J = 1 level. From sp...

2005
Marta Valledor Juan Carlos Campo Miguel A. Perez Juan C. Alvarez Juan C. Viera

− Phosphorescent sensors are usually based on measurement of light intensity or lifetime of sensor emitted light. This goal may be accomplished by measuring the phase-shift between the excitation and the emitted light. Scattered signals must be removed to perform the measurement; however, some of the scattered light due to fluorescence is impossible to remove when measuring phosphorescence deca...

Journal: :Inorganic chemistry 2003
Mohammad A Omary Manal A Rawashdeh-Omary Himashinie V K Diyabalanage H V Rasika Dias

The synthesis, structure, and photoluminescence properties are described for the three-coordinate mononuclear and dinuclear complexes [H(2)B(3,5-(CF(3))(2)Pz)(2)]M(2,4,6-collidine), M(1)(), and [[3,5-(CF(3))(2)Pz]M(2,4,6-collidine)](2), M(2)(), respectively (M = Cu; Ag). The solids exhibit bright blue phosphorescence, at room temperature for the copper compounds and at 77 K for all compounds. A...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید