نتایج جستجو برای: phakic intraocular lenses
تعداد نتایج: 31376 فیلتر نتایج به سال:
AIM To analyse how age-related losses in crystalline lens transmittance and pupillary area affect circadian photoreception and compare the circadian performance of phakic and pseudophakic individuals of the same age. METHODS The spectral sensitivity of circadian photoreception peaks in the blue part of the spectrum at approximately 460 nm. Photosensitive retinal ganglion cells send unconsciou...
Introduction: We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation: A 53-year-old woman had undergone toric implan...
PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...
Keratoconus is characterized by progressive corneal protrusion and thinning, leading to irregular astigmatism and impairment in visual function. The etiology and pathogenesis of the condition are not fully understood. However, significant strides have been made in early clinical detection of the disease, as well as towards providing optimal optical and surgical correction for improving the qual...
A 45-year-old man with bilateral high myopia and myopic astigmatism had uneventful implantation of a -10.5 diopters (D) Artisan iris-fixated anterior chamber phakic intraocular lens (PIOL) (Ophtec) in both eyes. In the first days after surgery, uncorrected visual acuity (UCVA) was 20/16 in the right eye and 20/16 in the left; the position of the PIOL was stable. Ten days after surgery, the left...
We report 2 patients who had radial keratotomy (RK) to correct myopia. The first patient developed a postoperative hyperopic shift and cataract. Nine years post RK, she had intracapsular cataract extraction and implantation of an Artisan aphakic intraocular lens (IOL). Twenty years post RK, hyperopia and astigmatism progressed to +7.0 -5.75 x 100 with a best corrected visual acuity (BCVA) of 20...
We describe a patient with flap decentration after laser in situ keratomileusis (LASIK) and subsequent phakic toric intraocular lens (IOL) implantation. A 19-year-old man with mixed astigmatism had LASIK in the left eye complicated by flap decentration. Laser ablation was abandoned and implantation of a phakic toric IOL was done. Ten months after IOL implantation, the uncorrected visual acuity ...
PURPOSE To evaluate postoperative astigmatism with regard to incision-induced astigmatism and deviation in axial alignment with the use of preoperative limbal marking with the Javal keratometer (Haag Streit, Bern, Switzerland) in eyes implanted with the Artisan toric phakic intraocular lens (IOL) (Ophtec, Groningen, The Netherlands). DESIGN Prospective nonrandomized trial. PARTICIPANTS Fift...
PURPOSE To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM). METHODS Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber dept...
PURPOSE To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in eyes with high hyperopia. METHODS We analyzed the results of 24 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of hyperopia with the goal of emmetropia. Mean follow...