نتایج جستجو برای: patient dosimetry
تعداد نتایج: 716269 فیلتر نتایج به سال:
The Technical Report Series 398 (TRS-398), Electron Dosimetry Working Party (EWDP), and Task Group 51 (TG 51) are the most important protocols for reference dosimetry. In case of electron beam dosimetry, these recommend using parallel-plate ionization chambers beams with R50 values below specific thresholds. However, recent papers suggested cylindrical dosimetry all energies. Here we compared d...
Table 1 Radiation dose (and comparative background radiation exposure) associated with various imaging techniques, including plain-film x-rays, computed tomography (CT) scans and computed tomography angiography (CTA) scans. Exposure calculated with ImPACT CT Patient Dosimetry Calculator (Version 0.99w, ImPACT, St. George’s The radiation exposure of Computed Tomographic Angiography (CTA) in DIEP...
Mandatory in several countries, in vivo dosimetry has been recognized as one of the next milestones in radiation oncology. Our department has implemented clinically an EPID based in vivo dosimetry system, EPIgray, by DOSISOFT S.A., since 2006. An analysis of the measurements per linac and energy over a two-year period was performed, which included a more detailed examination per technique and t...
Radionuclide therapy requires patient-specific planning of the absorbed dose to target volumes, in most cases tumours, in order to achieve an expected biological effect, taking into account that the absorbed doses to normal organs and tissues should be kept as low as reasonably achievable. Therefore, the calculation of absorbed doses has to be as accurate as possible. The accuracy depends on th...
The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple-channel dosimetry has recently been utilized in exte...
PURPOSE Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within ± 10% of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However...
In spite of considerable progress, much remains to be done in the estimation of absorbed doses to organs and tissues in the body and in the prediction of biological effects from radiopharmaceuticals. In patients undergoing diagnostic procedures, the biokinetics of the radionuclide has to be determined for a number of representative patients. When radiopharmaceuticals are used for therapy, it is...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید