نتایج جستجو برای: pardah pin

تعداد نتایج: 13656  

Journal: :Orthopedics 2011
Mohammad Taghi Peivandi Amir Reza Kachooei Zohreh Nazemian

Removing a broken guide wire is difficult and challenging. This article reports a method that was used to successfully remove a broken guide wire in 3 patients who underwent operative treatment for intertrochanteric fractures of the femur. Under general anesthesia, the first patient was placed on the orthopedic fracture table, and closed reduction of the hip fracture was performed under the ima...

Journal: :The Plant cell 2007
Joshua J Blakeslee Anindita Bandyopadhyay Ok Ran Lee Jozef Mravec Boosaree Titapiwatanakun Michael Sauer Srinivas N Makam Yan Cheng Rodolphe Bouchard Jirí Adamec Markus Geisler Akitomo Nagashima Tatsuya Sakai Enrico Martinoia Jirí Friml Wendy Ann Peer Angus S Murphy

Directional transport of the phytohormone auxin is established primarily at the point of cellular efflux and is required for the establishment and maintenance of plant polarity. Studies in whole plants and heterologous systems indicate that PIN-FORMED (PIN) and P-glycoprotein (PGP) transport proteins mediate the cellular efflux of natural and synthetic auxins. However, aromatic anion transport ...

Journal: :TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C 2001

Journal: :British Journal of Anaesthesia 1962

Journal: :JAMA: The Journal of the American Medical Association 1901

Journal: :JACC: Case Reports 2021

Journal: :Acta orthopaedica Scandinavica 2003
Annette W-Dahl Sören Toksvig-Larsen Anders Lindstrand

INTRODUCTION We investigated whether there were any differences in the frequency and severity of pin site infections by performing pin site care daily or once a week. We studied patients operated on for gonarthrosis by the hemicallotasis technique, using hydroxyapatite-coated pins in the metaphyseal bone and standard pins in the diaphyseal bone. PATIENTS AND METHODS 50 patients were prospecti...

2012
CaiChao Zhu XiangYang Xu Teik Chin Lim XueSong Du MingYong Liu

Flexible pins eliminate the need for straddle mounting, and therefore enable the maximum possible number of planets to be used for any particular epicyclic ratio of power transmission systems. Having more planet gears will significantly increase the input torque density. In this type of design, the pin stiffness and position tolerances are important parameters as they affect the dynamic perform...

2015
Alfred O. Ogbemudia Anirejuoritse Bafor Ehimwenma J. Ogbemudia Edwin Edomwonyi

Pin-track infection (PTI) is a common complication of external fixation. Antimicrobial dressings of the pin-site interface should reduce the severity and incidence of PTI. This study is aimed at determining the efficacy of 1 % silver sulphadiazine dressings in preventing PTI in external fixation. We compared the incidence of PTI between group A (dry sterile gauze dressing) and group B (1 % silv...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید