نتایج جستجو برای: occluder device
تعداد نتایج: 680147 فیلتر نتایج به سال:
Device closure of atrial septal defect with amplatzer septal occluder in adults- safety and outcome.
BACKGROUND Secundum atrial septal defect is a common congenital heart disease. Amplatzer septal occluder has become the most commonly used device for its closure. This study was conducted to determine the safety and outcome of atrial septal defect closure with the Amplatzer septal occlude (ASO). METHODS This Case-series was conducted at Armed Forces Institute of Cardiology/National Institute ...
Description Implant device and delivery system. The Ventricular Partitioning Device (VPD) is an intraventricular Implant that is deployed in the Left Ventricle (LV) in patients with regional wall motion abnormalities following myocardial infarction (MI). The implant device is delivered via a guiding catheter and delivery system introduced percutaneously from the femoral artery by the standard t...
We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device emb...
The Amplatzer septal occluder (ASO) has become the device of choice for interventional closure of atrial septal defects (ASDs) in many institutions during the last decades. Although excellent results have been reported for the device, concerns have arisen about the long-term complications (1). Of these complications, thrombus formation was rarely seen after 1 year in patients (2–4). This is the...
Transcatheter closure of secundum atrial septal defect has become an alternative to surgery. We present a patient with hemodynamic collapse secondary to cardiac perforation occurring 36 h after the placement of an Amplatzer Septal Occluder and discuss complications of this kind of device.
The surgical and transcatheter coil closure of coronary arterial fistulas are described in the literature. We report our experience with the successful transcatheter closure of a coronary arterial fistula, arising from the left coronary artery and draining into the right ventricle, with the new Amplatzer duct occluder II device.
A through review of the literature identified only 20 reported cases of fistula involving the internal mammary (internal thoracic) artery and a lobar branch of a pulmonary artery. Surgical closure was frequently done to avoid complications associated with this anomaly. We report the first patient in whom percutaneous treatment was accomplished with a combined technique involving an Amplatzer Du...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید