نتایج جستجو برای: multi focus fan beam collimator

تعداد نتایج: 906544  

Journal: :Int. J. Imaging Systems and Technology 2007
Deepak Bharkhada Hengyong Yu Kai Zeng Er-Wei Bai Ge Wang

Bai et al. recently proposed to acquire random fanbeam/cone-beam projections with a linear/planar detector from a circular scanning locus for controlled cardiac computed tomography (CT). After specifying a uniform acquisition geometry required by FBP (filtration-backprojection), we rebin the random fan-beam/cone-beam data via nearest-neighbor, quadrilateral and triangle-based linear interpolati...

Journal: :iranian journal of cancer prevention 0
a iftikhar center for nuclear medicine and radiotherapy (cenar), bmc complex, quetta, pakistan m wazir institute of nuclear medicine, oncology and radiotherapy, abbotabad, pakistan mb kakakhail pakistan institute of engineering and applied sciences (pieas) islamabad, pakistan a sbilal pakistan institute of engineering and applied sciences (pieas) islamabad, pakistan a khwaja center for nuclear medicine and radiotherapy (cenar), bmc complex, quetta, pakistan a khushnaseeb center for nuclear medicine and radiotherapy (cenar), bmc complex, quetta, pakistan

background: during radiotherapy treatment, critical organs are shielded using lead and cerrobend blocks. the objective of this study is to compare the effects of lead and cerrobend shielding blocks on incident photon beam. methods: collimator scatter factors were measured for open square fields (3 x 3 cm to 40 x 40 cm) defined by collimator jaws and for fields blocked down to smaller asymmetric...

2006
Igor Zagorodnov

Using a recently developed time domain numerical approach we calculate the short-range geometric wakefields of 3D collimators and compare with analytical models. We find, in the diffractive regime, that the transverse mode kick factor can be approximated from the change in field energy between the beam pipe and the collimator if the collimator is long, or using a “field clipping” estimate if it...

2011
Shaojie Tang Xuanqin Mou Yanbo Zhang Hengyong Yu

We propose a novel method to reduce the noise in fan-beam computed tomography (CT) imaging. First, the inverse Radon transform is induced for a family of differential expression of projection function. Second, the diffusion partial differential equation (PDE) is generalized from image space to projection space in parallel-beam geometry. Third, the diffusion PDE is further induced from parallel-...

2000
P. Tenenbaum K. Bane R. K. Jobe D. McCormick T. O. Raubenheimer M. Ross G. Stupakov D. Walz

We present a direct measurement of the short-range wakefield of a series of tapered collimators. The wakefields were measured by inserting a fixed aperture in the path of the electron beam at the 1.19 GeV point of the SLAC linac. As the vertical position of the collimator is varied, the vertical deflection of the beam is measured on 29 downstream beam position monitors. A series of apertures wi...

Journal: :Physics in medicine and biology 2004
J D Fenwick W A Tomé H A Jaradat S K Hui J A James J P Balog C N DeSouza D B Lucas G H Olivera T R Mackie B R Paliwal

Helical tomotherapy has been developed at the University of Wisconsin, and 'Hi-Art II' clinical machines are now commercially manufactured. At the core of each machine lies a ring-gantry-mounted short linear accelerator which generates x-rays that are collimated into a fan beam of intensity-modulated radiation by a binary multileaf, the modulation being variable with gantry angle. Patients are ...

Journal: :Physical Review Special Topics - Accelerators and Beams 2014

2015
S. Barros I. Bergström

In 2014 a new vertical flight path was installed at the neutron time-of-flight facility, n TOF, at CERN. The beam line optimization of this second experimental area (EAR2) was performed by FLUKA simulations with a detailed model of the facility, including the spallation target, neutron beam line, magnet, collimators and beam dump. The beam profile as well as neutron and gamma fluxes were calcul...

2006
Frank Zimmermann

We derive formulae for the coherent and incoherent tune shift due to the nonlinear resistive-wall wake field for a single beam travelling between two parallel plates. The theoretical predictions are compared with measurements performed on an LHC prototype collimator during the 2004 SPS run. We show that the tune shift derived from the nonlinear wake field yields a better agreement with the meas...

2017
K H Dekker

A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experim...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید